Treatment planning for capacitive regional hyperthermia

Capacitively coupled hyperthermia devices are widely in use, mainly in Asian countries. In this paper, a comprehensive treatment planning system, including a Specific Absorption Rate (SAR) and thermal model for capacitively coupled hyperthermia, is described and demonstrated using a heterogeneous pa...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of hyperthermia Vol. 19; no. 1; pp. 58 - 73
Main Authors Kroeze, H., Van de Kamer, J. B., De Leeuw, A. A. C., Kikuchi, M., Lagendijk, J. J. W.
Format Journal Article
LanguageEnglish
Published London Informa UK Ltd 2003
Taylor & Francis
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Capacitively coupled hyperthermia devices are widely in use, mainly in Asian countries. In this paper, a comprehensive treatment planning system, including a Specific Absorption Rate (SAR) and thermal model for capacitively coupled hyperthermia, is described and demonstrated using a heterogeneous patient model. In order to accurately model a hyperthermia treatment, simulation at high resolution is mandatory. Using the quasi-static approximation, the electromagnetic problem can be solved at high resolution with acceptable computational effort. The validity of the quasi-static approximation is demonstrated by comparing the Maxwell solution of a phantom problem to the quasi-static approximation. Modelling of capacitive hyperthermia of the prostate reveals the difficulty of heating deep-seated tumours in the pelvic area. Comparison of the SAR distribution in the heterogeneous patient model and a patient shaped agar phantom shows a shielding effect of the pelvic bone and the influence of the fat-muscle distribution. It is shown that evaluation of capacitive hyperthermia with agar phantoms leads to overly optimistic conclusions. Therapeutic relevant tumour temperatures can only be obtained by permitting temperature extrema in normal tissue. This concurs with clinical practice, where treatment-limiting hot spots restrict the tumour temperature. It is demonstrated that the use of very cold overlay bolus bags has only a very superficial effect. The presented model can be used for individual treatment planning and optimization, for the evaluation of capacitive applicator modifications and comparison with other devices.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0265-6736
1464-5157
DOI:10.1080/02656730210158464