Modeling and correction of bolus dispersion effects in dynamic susceptibility contrast MRI

Purpose Bolus dispersion in DSC‐MRI can lead to errors in cerebral blood flow (CBF) estimation by up to 70% when using singular value decomposition analysis. However, it might be possible to correct for dispersion using two alternative methods: the vascular model (VM) and control point interpolation...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 72; no. 6; pp. 1762 - 1774
Main Authors Mehndiratta, Amit, Calamante, Fernando, MacIntosh, Bradley J., Crane, David E., Payne, Stephen J., Chappell, Michael A.
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.12.2014
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.25077

Cover

Loading…
More Information
Summary:Purpose Bolus dispersion in DSC‐MRI can lead to errors in cerebral blood flow (CBF) estimation by up to 70% when using singular value decomposition analysis. However, it might be possible to correct for dispersion using two alternative methods: the vascular model (VM) and control point interpolation (CPI). Additionally, these approaches potentially provide a means to quantify the microvascular residue function. Methods VM and CPI were extended to correct for dispersion by means of a vascular transport function. Simulations were performed at multiple dispersion levels and an in vivo analysis was performed on a healthy subject and two patients with carotid atherosclerotic disease. Results Simulations showed that methods that could not address dispersion tended to underestimate CBF (ratio in CBF estimation, CBFratio = 0.57–0.77) in the presence of dispersion; whereas modified CPI showed the best performance at low‐to‐medium dispersion; CBFratio = 0.99 and 0.81, respectively. The in vivo data showed trends in CBF estimation and residue function that were consistent with the predictions from simulations. Conclusion In patients with atherosclerotic disease the estimated residue function showed considerable differences in the ipsilateral hemisphere. These differences could partly be attributed to dispersive effects arising from the stenosis when dispersion corrected CPI was used. It is thus beneficial to correct for dispersion in perfusion analysis using this method. Magn Reson Med 72:1762–1774, 2014. © 2014 Wiley Periodicals, Inc.
Bibliography:istex:C74AB369A6C917377503D5724B75FA9CFEEDA17C
ArticleID:MRM25077
ark:/67375/WNG-VVR9CGSS-4
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.25077