Chemometric processing of second-order liquid chromatographic data with UV–vis and fluorescence detection. A comparison of multivariate curve resolution and parallel factor analysis 2

[Display omitted] •Chemometric models for non-trilinear chromatographic data were compared.•Simulated and experimental systems of varying complexity were analyzed.•The limits of parallel factor analysis 2 were discussed in the simulation study.•Multivariate curve resolution algorithm seems more adeq...

Full description

Saved in:
Bibliographic Details
Published inAnalytica chimica acta Vol. 842; pp. 11 - 19
Main Authors Bortolato, Santiago A., Olivieri, Alejandro C.
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 09.09.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:[Display omitted] •Chemometric models for non-trilinear chromatographic data were compared.•Simulated and experimental systems of varying complexity were analyzed.•The limits of parallel factor analysis 2 were discussed in the simulation study.•Multivariate curve resolution algorithm seems more adequate in a general case. Second-order liquid chromatographic data with multivariate spectral (UV–vis or fluorescence) detection usually show changes in elution time profiles from sample to sample, causing a loss of trilinearity in the data. In order to analyze them with an appropriate model, the latter should permit a given component to have different time profiles in different samples. Two popular models in this regard are multivariate curve resolution-alternating least-squares (MCR-ALS) and parallel factor analysis 2 (PARAFAC2). The conditions to be fulfilled for successful application of the latter model are discussed on the basis of simple chromatographic concepts. An exhaustive analysis of the multivariate calibration models is carried out, employing both simulated and experimental chromatographic data sets. The latter involve the quantitation of benzimidazolic and carbamate pesticides in fruit and juice samples using liquid chromatography with diode array detection, and of polycyclic aromatic hydrocarbons in water samples, in both cases in the presence of potential interferents using liquid chromatography with fluorescence spectral detection, thereby achieving the second-order advantage. The overall results seem to favor MCR-ALS over PARAFAC2, especially in the presence of potential interferents.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0003-2670
1873-4324
DOI:10.1016/j.aca.2014.07.007