Attenuation in Peripheral Endothelial Function After Continuous Flow Left Ventricular Assist Device Therapy Is Associated With Cardiovascular Adverse Events

Background:Patients with heart failure (HF) have abnormal endothelial function. Although use of a continuous flow left ventricular assist device (CF-LVAD) results in significant hemodynamic improvement, the effects on systemic endothelial function are unclear.Methods and Results:Eighteen HF patients...

Full description

Saved in:
Bibliographic Details
Published inCirculation Journal Vol. 79; no. 4; pp. 770 - 777
Main Authors Hasin, Tal, Matsuzawa, Yasushi, Guddeti, Raviteja R., Aoki, Tatsuo, Kwon, Taek-Geun, Schettle, Sarah, Lennon, Ryan J., Chokka, Ramesh G., Lerman, Amir, Kushwaha, Sudhir S.
Format Journal Article
LanguageEnglish
Published Japan The Japanese Circulation Society 2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background:Patients with heart failure (HF) have abnormal endothelial function. Although use of a continuous flow left ventricular assist device (CF-LVAD) results in significant hemodynamic improvement, the effects on systemic endothelial function are unclear.Methods and Results:Eighteen HF patients with CF-LVAD implantation were included in this prospective observational study. We measured reactive hyperemia index (RHI) before and after CF-LVAD implantation to evaluate sequential changes in endothelial function. Patients were followed clinically for the occurrence of adverse cardiovascular events, a composite of death, thrombosis, bleeding, HF, renal failure, and arrhythmia. Preoperative RHI was 1.77±0.39. Early in the postoperative period (7–14 days after operation) RHI significantly decreased to 1.19±0.31 (P<0.001, compared with preoperative RHI). At first and second follow-up (4–6 weeks and 3–7 months after operation) RHI remained lower at 1.48±0.50 (P=0.030) and 1.26±0.37 (P=0.002), respectively, compared with preoperative RHI. The decrease in early postoperative RHI relative to preoperative RHI was significantly associated with adverse cardiovascular events after CF-LVAD (age-adjusted risk ratio for 0.25 decrease in RHI, 1.35; 95% confidence interval: 1.13–1.62, P=0.001).Conclusions:Peripheral endothelial function had a significant and persistent decline up to 5 months following implantation of CF-LVAD, and this decline was associated with adverse cardiovascular events. These findings may provide insight into some of the vascular complications following CF-LVAD in HF patients. (Circ J 2015; 79: 770–777)
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1346-9843
1347-4820
DOI:10.1253/circj.CJ-14-1079