Attenuation in Peripheral Endothelial Function After Continuous Flow Left Ventricular Assist Device Therapy Is Associated With Cardiovascular Adverse Events
Background:Patients with heart failure (HF) have abnormal endothelial function. Although use of a continuous flow left ventricular assist device (CF-LVAD) results in significant hemodynamic improvement, the effects on systemic endothelial function are unclear.Methods and Results:Eighteen HF patients...
Saved in:
Published in | Circulation Journal Vol. 79; no. 4; pp. 770 - 777 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Japan
The Japanese Circulation Society
2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background:Patients with heart failure (HF) have abnormal endothelial function. Although use of a continuous flow left ventricular assist device (CF-LVAD) results in significant hemodynamic improvement, the effects on systemic endothelial function are unclear.Methods and Results:Eighteen HF patients with CF-LVAD implantation were included in this prospective observational study. We measured reactive hyperemia index (RHI) before and after CF-LVAD implantation to evaluate sequential changes in endothelial function. Patients were followed clinically for the occurrence of adverse cardiovascular events, a composite of death, thrombosis, bleeding, HF, renal failure, and arrhythmia. Preoperative RHI was 1.77±0.39. Early in the postoperative period (7–14 days after operation) RHI significantly decreased to 1.19±0.31 (P<0.001, compared with preoperative RHI). At first and second follow-up (4–6 weeks and 3–7 months after operation) RHI remained lower at 1.48±0.50 (P=0.030) and 1.26±0.37 (P=0.002), respectively, compared with preoperative RHI. The decrease in early postoperative RHI relative to preoperative RHI was significantly associated with adverse cardiovascular events after CF-LVAD (age-adjusted risk ratio for 0.25 decrease in RHI, 1.35; 95% confidence interval: 1.13–1.62, P=0.001).Conclusions:Peripheral endothelial function had a significant and persistent decline up to 5 months following implantation of CF-LVAD, and this decline was associated with adverse cardiovascular events. These findings may provide insight into some of the vascular complications following CF-LVAD in HF patients. (Circ J 2015; 79: 770–777) |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 1346-9843 1347-4820 |
DOI: | 10.1253/circj.CJ-14-1079 |