Analytical Performance of a Novel Latex Turbidimetric Immunoassay, “Nanopia TARC”, for TARC/CCL17 Measurement: A Retrospective Observational Study

Thymus- and activation-regulated chemokine (TARC, also known as CCL17) is used as a biomarker for atopic dermatitis. The methods currently used for its measurement are complex, time-consuming, and require large machinery, warranting the need for a method that is simple, has a quick turnaround time,...

Full description

Saved in:
Bibliographic Details
Published inDiagnostics (Basel) Vol. 13; no. 18; p. 2935
Main Authors Yamashita, Keita, Takebayashi, Shiori, Murata, Wataru, Hirai, Nao, Ito, Yui, Mitsui, Mayuka, Saito, Mina, Sato, Kei, Terada, Miyuki, Niizeki, Noriyasu, Suzuki, Akira, Ogitani, Kenya, Fujikawa, Toshihiko, Komori, Marie, Inoue, Nozomi, Arai, Norimitsu, Maekawa, Masato
Format Journal Article
LanguageEnglish
Published Basel MDPI AG 01.09.2023
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Thymus- and activation-regulated chemokine (TARC, also known as CCL17) is used as a biomarker for atopic dermatitis. The methods currently used for its measurement are complex, time-consuming, and require large machinery, warranting the need for a method that is simple, has a quick turnaround time, and requires less complex machinery. We evaluated the analytical performance of a novel latex turbidimetric immunoassay method, “Nanopia TARC”, on 174 residual serum samples from patients with skin or allergic diseases. This evaluation included the assessment of the limit of blank/detection/quantification (LOB/D/Q), precision, accuracy, linearity, interference, and commutability between Nanopia TARC and “HISCL TARC”, based on the chemiluminescent enzyme immunoassay (CLEIA) method. The LOB/D/Q values were 13, 57, and 141 pg/mL, respectively. The coefficient of variation of the repeatability was 0.9–3.8%, and that of the intermediate precision was 2.1–5.4%. The total error of the accuracy was 1.9–13.4%. The linearity was 141 and 19,804 pg/mL for TARC. The correlation coefficient between Nanopia TARC and HISCL TARC determined using the Passing–Bablok regression analysis was 0.999. Furthermore, the concordance of diagnostic criteria with AD was 92%. Nanopia TARC was confirmed to have the same analytical performance for TARC measurement as the existing CLEIA method.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2075-4418
2075-4418
DOI:10.3390/diagnostics13182935