Evaluation of the safety and efficacy of the picosecond alexandrite laser with specialized lens array for treatment of the photoaging décolletage

Background Fractionated lasers are routinely used to treat the characteristic cutaneous signs of photoaging. In this study, we evaluate the use of picosecond pulse duration combined with a diffractive lens array for treatment of photodamage of the décolletage. Methods Twenty subjects with Fitzpatric...

Full description

Saved in:
Bibliographic Details
Published inLasers in surgery and medicine Vol. 48; no. 2; pp. 188 - 192
Main Authors Wu, Douglas C., Fletcher, Leysin, Guiha, Isabella, Goldman, Mitchel P.
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.02.2016
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Fractionated lasers are routinely used to treat the characteristic cutaneous signs of photoaging. In this study, we evaluate the use of picosecond pulse duration combined with a diffractive lens array for treatment of photodamage of the décolletage. Methods Twenty subjects with Fitzpatrick skin types I–IV were enrolled in a prospective open‐label trial evaluating the efficacy of the 755 nm picosecond pulsed alexandrite laser with diffractive lens array for treatment of photodamage to the décolletage. Each subject received a series of four laser treatments at 3 week intervals. Follow up evaluation was performed 1 and 3 months later by a masked investigator and consisted of assessment of dyspigmentation, erythema, keratosis, texture, and rhytides on a standardized 5 point scale; global aesthetic improvement 5 point scale; and investigator and subject satisfaction questionnaire. Adverse events and treatment discomfort was also assessed. Results Statistically significant improvement in dyspigmentation, keratosis, and skin texture were observed at both 1 and 3 month follow up intervals (P < 0.05). rhytides initially demonstrated significant improvement at the 1 month time point, but this significance was not maintained at 3 months (P = 0.08). There was no statistically significant improvement noted in erythema. The majority of subjects were satisfied, with a mean rating of 2.8/6 (one being extremely satisfied and six being extremely dissatisfied). Subject pain was 3.6/10. Conclusion The 755 nm picosecond pulsed alexandrite laser with diffractive lens array can be an effective option for rejuvenation of the photodamaged décolletage. Lasers Surg. Med. 48:188–192, 2016. © 2015 Wiley Periodicals, Inc.
Bibliography:istex:E07B1E51E24DDC107BC0B16BC66F334BD3DD380D
ArticleID:LSM22427
Cynosure
ark:/67375/WNG-7V0GK3TD-K
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:0196-8092
1096-9101
DOI:10.1002/lsm.22427