Planimetry of Mitral Valve Stenosis by Magnetic Resonance Imaging

We sought to determine whether noninvasive planimetry of the mitral valve area (MVA) by magnetic resonance imaging (MRI) is feasible and reliable in patients with mitral stenosis (MS). Accurate assessment of MVA is particularly important for the management of patients with valvular stenosis. Current...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American College of Cardiology Vol. 45; no. 12; pp. 2048 - 2053
Main Authors Djavidani, Behrus, Debl, Kurt, Lenhart, Markus, Seitz, Johannes, Paetzel, Christian, Schmid, Franz X., Nitz, Wolfgang R., Feuerbach, Stefan, Riegger, Günter, Luchner, Andreas
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 21.06.2005
Elsevier Science
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We sought to determine whether noninvasive planimetry of the mitral valve area (MVA) by magnetic resonance imaging (MRI) is feasible and reliable in patients with mitral stenosis (MS). Accurate assessment of MVA is particularly important for the management of patients with valvular stenosis. Current standard techniques for assessing the severity of MS include echocardiography (ECHO) and cardiac catheterization (CATH). In 22 patients with suspected or known MS, planimetry of MVA was performed with a 1.5-T magnetic resonance scanner using a breath-hold balanced gradient echo sequence (true FISP). Data were compared with echocardiographically determined MVA (ECHO-MVA, n = 22), as well as with invasively calculated MVA by the Gorlin-formula at (CATH-MVA, n = 17). The correlation between MRI- and CATH-MVA was 0.89 (p < 0.0001), and the correlation between MRI- and ECHO-MVA was 0.81 (p < 0.0001). The MRI-MVA slightly overestimated CATH-MVA by 5.0% (1.60 ± 0.45 cm2vs. 1.52 ± 0.49 cm2, p = NS) and ECHO-MVA by 8.1% (1.61 ± 0.42 cm2vs. 1.48 ± 0.42 cm2, p < 0.05). On receiver-operating characteristic curve analysis, a value of MRI-MVA below 1.65 cm2indicated mitral stenosis (CATH-MVA ≤1.5 cm2), with a good sensitivity and specificity (89% and 75%, respectively). Magnetic resonance planimetry of the mitral valve orifice in mitral stenosis offers a reliable and safe method for noninvasive quantification of mitral stenosis. In the clinical management of patients with mitral stenosis, it has to be considered that planimetry by MRI slightly overestimates MVA, as compared with MVA calculated echocardiographically and at catheterization.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0735-1097
1558-3597