Analysis of sub-ppb levels of Fe(II), Co(II), and Ni(II) by electrokinetic supercharging preconcentration, CZE separation, and in-capillary derivatization

The analysis of sub-ppb levels of Fe(II), Co(II), and Ni(II) in heat exchanger fluids of nuclear power plants is needed to monitor corrosion. A method involving preconcentration with electrokinetic supercharging (electrokinetic injection with transient ITP), CZE separation, and in-capillary derivati...

Full description

Saved in:
Bibliographic Details
Published inElectrophoresis Vol. 28; no. 20; pp. 3767 - 3776
Main Authors Urbanek, Marek, Delaunay, Nathalie, Michel, Régis, Varenne, Anne, Gareil, Pierre
Format Journal Article
LanguageEnglish
Published Weinheim Wiley-VCH Verlag 01.10.2007
WILEY-VCH Verlag
WILEY‐VCH Verlag
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The analysis of sub-ppb levels of Fe(II), Co(II), and Ni(II) in heat exchanger fluids of nuclear power plants is needed to monitor corrosion. A method involving preconcentration with electrokinetic supercharging (electrokinetic injection with transient ITP), CZE separation, and in-capillary derivatization with ortho-phenanthroline (o-Phe) for direct UV detection was thus developed. First, a multizone BGE was loaded into the capillary by successive hydrodynamic introduction of zones of (i) o-Phe-containing BGE, (ii) BGE for the zonal separation, and (iii) ammonium-based leading electrolyte. Metal cations were electrokinetically injected and stacked at the capillary inlet behind this last leading zone. Finally, a terminating electrolyte zone was hydrodynamically introduced. When a constant voltage was applied, metal ions kept on concentrating isotachophoretically, then separated in CZE mode, were complexed by migrating through an o-Phe zone, and finally detected by direct absorbance. To detect extremely thin peaks, it was attempted for the first time to focus the derivatization reagent by inducing a second transient ITP, before labeling analytes, already separated in CZE mode. With this arrangement, LODs were about 30 ppt in pure water. In heat exchanger fluid matrices containing 1000 ppm bore and 2 ppm lithium, only Fe(II) cation was detected among the three cations of interest at the 1 ppb level using the present method, and its LOD was about ten times higher, due to the lower loading rate during electrokinetic injection.
Bibliography:http://dx.doi.org/10.1002/elps.200700180
istex:1AE20E1B392875CC62C5F860E7D604C04B6B57ED
ark:/67375/WNG-H1VQ5VD5-N
ArticleID:ELPS200700180
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0173-0835
1522-2683
DOI:10.1002/elps.200700180