Comparison of Resorbable Mesh (Poly L-Lactide/Glycolic Acid) and Porous Polyethylene in Orbital Floor Fractures in an Experimental Model

Background: Resorbable mesh and porous polyethylene are frequently used alloplastic materials for the treatment of the orbital blowout fractures. The literature lacks reports comparing their long-term effects on experimental models. Objective: Our aim was to radiologically and histologically evaluat...

Full description

Saved in:
Bibliographic Details
Published inCanadian journal of plastic surgery Vol. 25; no. 3; pp. 163 - 170
Main Authors Aral, Ali Mubin, Özmen, Selahattin, Uygur, Safak, Kaya, Basar, Coskun, Neslihan, Ömeroglu, Suna, Kılıc, Koray
Format Journal Article
LanguageEnglish
French
Published Los Angeles, CA SAGE Publications 01.08.2017
SAGE PUBLICATIONS, INC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background: Resorbable mesh and porous polyethylene are frequently used alloplastic materials for the treatment of the orbital blowout fractures. The literature lacks reports comparing their long-term effects on experimental models. Objective: Our aim was to radiologically and histologically evaluate the effectiveness and safety of porous polyethylene and resorbable mesh in a rabbit orbital blowout fracture model. Methods: Twelve New Zealand white rabbits (24 orbits) were randomized to 4 groups. In group 1, only orbital floor dissection was done. In group 2, following orbital floor dissection, a 10-mm defect was created without any extra procedure. In group 3, following a 10-mm defect creation, a 12-mm-round cut porous polyethylene was placed on the defect. In group 4, following a 10-mm defect creation, a 12-mm-round cut resorbable mesh was placed on the defect. Computed tomographic analysis was performed during follow-up period. Orbital floors were evaluated histologically at month 6. Results: No clinical complications were observed during follow-up period. In radiological evaluation, there was no statistically significant difference between groups regarding bone formation. In histological evaluation, the connective tissue was denser, and organized and better bone formation was observed in group 3 and 4 when compared with other groups. Conclusion: Although no significant radiological changes were present, porous polyethylene and resorbable mesh performed better histologically. They were effective and well tolerated for reconstruction of the isolated orbital floor defects.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2292-5503
2292-5511
DOI:10.1177/2292550317702370