Inner-volume imaging in vivo using three-dimensional parallel spatially selective excitation

This work describes the first experimental realization of three‐dimensional spatially selective excitation using parallel transmission in vivo. For the design of three‐dimensional parallel excitation pulses with short durations and high excitation accuracy, the choice of a suitable transmit k‐space...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 69; no. 5; pp. 1367 - 1378
Main Authors Schneider, Johannes T., Kalayciyan, Raffi, Haas, Martin, Herrmann, Sarah R., Ruhm, Wolfgang, Hennig, Jürgen, Ullmann, Peter
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.05.2013
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This work describes the first experimental realization of three‐dimensional spatially selective excitation using parallel transmission in vivo. For the design of three‐dimensional parallel excitation pulses with short durations and high excitation accuracy, the choice of a suitable transmit k‐space trajectory is crucial. For this reason, the characteristics of a stack‐of‐spirals trajectory and of a concentric‐shells trajectory were examined in an initial simulation study. It showed that, especially when undersampling the trajectories in combination with parallel transmission, experimental parameters such as transmit‐coil geometry and off‐resonance conditions have an essential impact on the suitability of the selected trajectory and undersampling scheme. Both trajectories were applied in MR inner‐volume imaging experiments which demonstrate that acceptably short and robust three‐dimensional selective pulses can be achieved if the trajectory is temporally optimized and its actual path is measured and considered during pulse calculation. Pulse durations as short as 3.2 ms were realized and such pulses were appropriate to accurately excite arbitrarily shaped volumes in a corn cob and in a rat in vivo. Reduced field‐of‐view imaging of these selectively excited targets allowed high spatial resolution and significantly reduced measurement times and furthermore demonstrates the feasibility of three‐dimensional parallel excitation in realistic MRI applications in vivo. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Bibliography:ArticleID:MRM24381
istex:773B5A7A74197694C1CBC550C07424070B63E7CB
ark:/67375/WNG-8QMD98S3-8
German Federal Ministry of Education and Research (INUMAC project) - No. 13N9207
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0740-3194
1522-2594
DOI:10.1002/mrm.24381