Changes in left ventricular electromechanical relations during targeted hypothermia
Background Targeted hypothermia, as used after cardiac arrest, increases electrical and mechanical systolic duration. Differences in duration of electrical and mechanical systole are correlated to ventricular arrhythmias. The electromechanical window (EMW) becomes negative when the electrical systol...
Saved in:
Published in | Intensive care medicine experimental Vol. 8; no. 1; p. 76 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Cham
Springer International Publishing
14.12.2020
Springer Nature B.V SpringerOpen |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
Targeted hypothermia, as used after cardiac arrest, increases electrical and mechanical systolic duration. Differences in duration of electrical and mechanical systole are correlated to ventricular arrhythmias. The electromechanical window (EMW) becomes negative when the electrical systole outlasts the mechanical systole. Prolonged electrical systole corresponds to prolonged QT interval, and is associated with increased dispersion of repolarization and mechanical dispersion. These three factors predispose for arrhythmias. The electromechanical relations during targeted hypothermia are unknown.
We wanted to explore the electromechanical relations during hypothermia at 33 °C. We hypothesized that targeted hypothermia would increase electrical and mechanical systolic duration without more profound EMW negativity, nor an increase in dispersion of repolarization and mechanical dispersion.
Methods
In a porcine model (
n
= 14), we registered electrocardiogram (ECG) and echocardiographic recordings during 38 °C and 33 °C, at spontaneous and atrial paced heart rate 100 beats/min. EMW was calculated by subtracting electrical systole; QT interval, from the corresponding mechanical systole; QRS onset to aortic valve closure. Dispersion of repolarization was measured as time from peak to end of the ECG T wave. Mechanical dispersion was calculated by strain echocardiography as standard deviation of time to peak strain.
Results
Electrical systole increased during hypothermia at spontaneous heart rate (
p
< 0.001) and heart rate 100 beats/min (
p
= 0.005). Mechanical systolic duration was prolonged and outlasted electrical systole independently of heart rate (
p
< 0.001). EMW changed from negative to positive value (− 20 ± 19 to 27 ± 34 ms,
p
= 0.001). The positivity was even more pronounced at heart rate 100 beats/min (− 25 ± 26 to 41 ± 18 ms,
p
< 0.001). Dispersion of repolarization decreased (
p
= 0.027 and
p
= 0.003), while mechanical dispersion did not differ (
p
= 0.078 and
p
= 0.297).
Conclusion
Targeted hypothermia increased electrical and mechanical systolic duration, the electromechanical window became positive, dispersion of repolarization was slightly reduced and mechanical dispersion was unchanged. These alterations may have clinical importance. Further clinical studies are required to clarify whether corresponding electromechanical alterations are accommodating in humans. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2197-425X 2197-425X |
DOI: | 10.1186/s40635-020-00363-7 |