Repair of radial fractures in Toy breed dogs with self-reinforced biodegradable bone plates, metal screws, and light-weight external coaptation

Objective— To describe a surgical technique for, and outcome after, treatment of radial fractures with biodegradable self‐reinforced polylactide plates and metal screws, and external coaptation. Study Design— Prospective clinical study. Sample Population— Eleven Toy breed dogs. Methods— Radial fract...

Full description

Saved in:
Bibliographic Details
Published inVeterinary surgery Vol. 34; no. 1; pp. 11 - 17
Main Authors Saikku-Backstrom, A, Raiha, J.E, Valimaa, T, Tulamo, R.M
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Science Inc 2005
Blackwell Publishing Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective— To describe a surgical technique for, and outcome after, treatment of radial fractures with biodegradable self‐reinforced polylactide plates and metal screws, and external coaptation. Study Design— Prospective clinical study. Sample Population— Eleven Toy breed dogs. Methods— Radial fractures were repaired by application of a single or 2 stacked biodegradable self‐reinforced polylactide plates (poly‐l/d, l‐lactide, stereocopolymer [ll‐and dl‐lactide ratio 70/30]; SR‐PLA (70/30) implants) secured with metal screws, and light‐weight external coaptation. Healing was evaluated clinically and by radiography at 2, 4, 6, 8, 9, 12, 24–26 weeks, and at 1 and 2 years. Owners were interviewed 3 years after surgery. Results— Radial fracture lines disappeared within 4–14 weeks in 10 dogs; an implant failed in 1 dog. Ambulation was excellent for healed fractures. Excessive skin tension led to removal of implants in 1 dog and suture repair in another dog. No foreign body reaction from implant degradation was observed and the plate was usually no longer palpable at 2 years. One dog had a fracture through a screw hole at 1 year. Conclusion— Healing and complication rates after repair of radial fractures with SR‐PLA (70/30) plates were considered similar or better than reported after repair with metallic plates or external fixation in Toy breed dogs. No radiographic signs of osteopenia were identified under the plate during follow‐up. Clinical Relevance— Biodegradable polylactide plates could be considered as an alternative to metal plates for radial fracture repair in Toy breed dogs, however available plates are likely not strong enough when used as a single plate. Implant removal is usually not needed.
Bibliography:istex:D95E2A59CA4702C544FEBA9E5B2D617FD9499264
ark:/67375/WNG-70MWWKRN-6
ArticleID:VSU00003
Preliminary results of the study were presented at the ESVOT/VOS meeting, Mûnich, Germany, September 6, 2002.
This study was supported by grants from the Finnish Ministry of Education and the Academy of Finland.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0161-3499
1532-950X
DOI:10.1111/j.1532-950X.2005.00003.x