Finite element analysis of balloon-expandable coronary stent deployment: Influence of angioplasty balloon configuration

SUMMARYToday, the majority of coronary stents are balloon‐expandable and are deployed using a balloon‐tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty ball...

Full description

Saved in:
Bibliographic Details
Published inInternational journal for numerical methods in biomedical engineering Vol. 29; no. 11; pp. 1161 - 1175
Main Authors Martin, David, Boyle, Fergal
Format Journal Article
LanguageEnglish
Published England Blackwell Publishing Ltd 01.11.2013
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:SUMMARYToday, the majority of coronary stents are balloon‐expandable and are deployed using a balloon‐tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty balloon is governed by the material properties of the balloon membrane, its folded configuration and its attachment to the catheter. Despite this observation, however, an optimum strategy for modelling the configuration of the angioplasty balloon in finite element studies of coronary stent deployment has not been identified, and idealised models of the angioplasty balloon are commonly employed in the literature. These idealised models often neglect complex geometrical features, such as the folded configuration of the balloon membrane and its attachment to the catheter, which may have a significant influence on the deployment of a stent. In this study, three increasingly sophisticated models of a typical semi‐compliant angioplasty balloon were employed to determine the influence of angioplasty balloon configuration on the deployment of a stent. The results of this study indicate that angioplasty balloon configuration has a significant influence on both the transient behaviour of the stent and its impact on the mechanical environment of the coronary artery. Copyright © 2013 John Wiley & Sons, Ltd. To date, an optimum strategy for modelling the configuration of the angioplasty balloon in finite element studies of balloon‐expandable coronary stent deployment has not been identified. In this study, three increasingly sophisticated models of a typical semi‐compliant angioplasty balloon were employed to determine the influence of angioplasty balloon configuration on the deployment of a stent. The results of this study indicate that angioplasty balloon configuration has a significant influence on both the transient behaviour of the stent and its impact on the mechanical environment of the coronary artery.
Bibliography:ark:/67375/WNG-1T4MPQWR-C
ArticleID:CNM2557
istex:FBC937B629F5E94D9EDA920FF27482909FE16512
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2040-7939
2040-7947
DOI:10.1002/cnm.2557