Rapid screening procedure based on headspace solid-phase microextraction and gas chromatography–mass spectrometry for the detection of many recreational drugs in hair
An increasing number of synthetic drugs are appearing on the illicit market and on the scene of drug use by youngsters. Official figures are underestimated. In addition, immunochemical tests are blind to many of these drugs and appropriate analytical procedures for routine clinical and epidemiologic...
Saved in:
Published in | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Vol. 801; no. 2; pp. 289 - 296 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Amsterdam
Elsevier B.V
05.03.2004
Elsevier Science |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | An increasing number of synthetic drugs are appearing on the illicit market and on the scene of drug use by youngsters. Official figures are underestimated. In addition, immunochemical tests are blind to many of these drugs and appropriate analytical procedures for routine clinical and epidemiological purposes are lacking. Therefore, the perceived increasing abuse of recreational drugs has not been proved yet. In a previous paper, we proposed a procedure for the preliminary screening of several recreational substances in hair and other biological matrices. Unfortunately, this procedure cannot apply to cocaine. Consequently, we performed a new headspace solid-phase microextraction and gas chromatography–mass spectrometry (HS-SPME–GC–MS) procedure for the simultaneous detection of cocaine, amphetamine (A), methamphetamine (MA), methylen-dioxyamphetamine (MDA), methylen-dioxymethamphetamine (MDMA), methylen-dioxyethamphetamine (MDE),
N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine (MBDB), ketamine, and methadone in human hair. Hair was washed with water and acetone in an ultrasonic bath. A short acid extraction with 1
M hydrochloric acid was needed; the fiber was exposed to a 5
min absorption at 90
°C and thermal desorption was performed at 250
°C for 3
min. The procedure was simple, rapid, required small quantities of sample and no derivatization. Good linearity was obtained over the 0.1–20.0
ng/mg range for the target compounds. Sensitivity was good enough: limits of detection (LOD) were 0.7
ng/mg of hair for the majority of substances. The intra-day precision ranged between 7 and 20%. This paper deals with the analytical performance of this procedure and its preliminary application to hair samples obtained on a voluntary basis from 183 young people (138 males and 45 females) in the Rome area. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1570-0232 1873-376X |