Infection Rates of Electrical Leads Used for Percutaneous Neurostimulation of the Peripheral Nervous System

Background Percutaneous neurostimulation of the peripheral nervous system involves the insertion of a wire “lead” through an introducing needle to target a nerve/plexus or a motor point within a muscle. Electrical current may then be passed from an external generator through the skin via the lead fo...

Full description

Saved in:
Bibliographic Details
Published inPain practice Vol. 17; no. 6; pp. 753 - 762
Main Authors Ilfeld, Brian M., Gabriel, Rodney A., Saulino, Michael F., Chae, John, Peckham, P. Hunter, Grant, Stuart A., Gilmore, Christopher A., Donohue, Michael C., deBock, Matthew G., Wongsarnpigoon, Amorn, Boggs, Joseph W.
Format Journal Article
LanguageEnglish
Published United States 01.07.2017
Subjects
Online AccessGet full text
ISSN1530-7085
1533-2500
1533-2500
DOI10.1111/papr.12523

Cover

Loading…
More Information
Summary:Background Percutaneous neurostimulation of the peripheral nervous system involves the insertion of a wire “lead” through an introducing needle to target a nerve/plexus or a motor point within a muscle. Electrical current may then be passed from an external generator through the skin via the lead for various therapeutic goals, including providing analgesia. With extended use of percutaneous leads sometimes greater than a month, infection is a concern. It was hypothesized that the infection rate of leads with a coiled design is lower than for leads with a noncoiled cylindrical design. Methods The literature was retrospectively reviewed for clinical studies of percutaneous neurostimulation of the peripheral nervous system of greater than 2 days that included explicit information on adverse events. The primary endpoint was the number of infections per 1,000 indwelling days. Results Forty‐three studies were identified that met inclusion criteria involving coiled (n = 21) and noncoiled (n = 25) leads (3 studies involved both). The risk of infection with noncoiled leads was estimated to be 25 times greater than with coiled leads (95% confidence interval [CI] 2 to 407, P = 0.006). The infection rates were estimated to be 0.03 (95% CI 0.01 to 0.13) infections per 1,000 indwelling days for coiled leads and 0.83 (95% CI 0.16 to 4.33) infections per 1,000 indwelling days for noncoiled leads (P = 0.006). Conclusions Percutaneous leads used for neurostimulation of the peripheral nervous system have a much lower risk of infection with a coiled design compared with noncoiled leads: approximately 1 infection for every 30,000 vs. 1,200 indwelling days, respectively.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-3
content type line 23
ISSN:1530-7085
1533-2500
1533-2500
DOI:10.1111/papr.12523