Comparing the monoisocentric and dual isocentric techniques in chest wall radiotherapy of mastectomy patients

The monoisocentric (MIT) and dual isocentric (DIT) techniques are compared for the mastectomy patients undergoing chest wall radiotherapy, and a new practical method is suggested for determining the dose calculation reference point to be used in the MIT. Data of 18 mastectomy patients having chest w...

Full description

Saved in:
Bibliographic Details
Published inJournal of applied clinical medical physics Vol. 16; no. 1; pp. 130 - 138
Main Authors Banaei, Amin, Hashemi, Bijan, Bakhshandeh, Mohsen
Format Journal Article
LanguageEnglish
Published United States John Wiley & Sons, Inc 01.01.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The monoisocentric (MIT) and dual isocentric (DIT) techniques are compared for the mastectomy patients undergoing chest wall radiotherapy, and a new practical method is suggested for determining the dose calculation reference point to be used in the MIT. Data of 18 mastectomy patients having chest wall radiotherapy were used. To find the appropriate dose calculation reference point for the MIT, the target tissue was divided into nine regions with 17 points as the appropriate candidates. After finding the best reference point for the MIT, dose calculations were made for each patient based on the MIT and DIT to determine the dose distributions of the target volume and organs at risk. The lateral component of the dose calculation reference point was found to be located at one‐third of the distance between the geometrical center and the lateral border of the chest wall in the lateral direction toward the outer border. The longitudinal component of this point was found to be located at the geometrical center of the chest wall with a depth located around 2–3 cm under the patients’ skin. There was no significant difference between the two radiotherapy planning techniques (MIT and DIT) regarding the dose distributions in the organs at risk and the 95% of the prescribed dose coverage of the target tissue. However, a significant difference for the 105% of the prescribed dose coverage, maximum dose delivered to the target tissue, and the level 2 lymph nodes dose was found, with the DIT showing higher values. Because of the good matching and no superposition observed between the treatment fields in the MIT, it was expected and confirmed that the hot and cold regions (with higher and lower doses than the prescribed dose) with the MIT are significantly fewer than that of the DIT. Therefore, to perform a better conformal radiotherapy for the patients having mastectomy, it could be recommended to use the MIT instead of the DIT and other conventional techniques. PACS numbers: 87.53.Bn, 87.53.Kn, 87.55.D‐, 87.55.ne
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1526-9914
1526-9914