Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research

Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. To determine the intra and inter...

Full description

Saved in:
Bibliographic Details
Published inSão Paulo medical journal Vol. 139; no. 5; pp. 424 - 434
Main Authors Pereiro-Buceta, Héctor, Calvo-Lobo, César, Becerro-de-Bengoa-Vallejo, Ricardo, Losa-Iglesias, Marta Elena, Romero-Morales, Carlos, López-López, Daniel, Martínez-Jiménez, Eva-María
Format Journal Article
LanguageEnglish
Published Brazil Associação Paulista de Medicina - APM 01.08.2021
Associação Paulista de Medicina
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. To determine the intra and intersession repeatability and reliability of dynamic parameters of the Podoprint pressure platform under simulated LLD conditions. Observational cross-sectional study at a public university. Thirty-seven healthy volunteers participated in this study. LLD was simulated using ethyl vinyl acetate plantar lifts with heights of 5 mm, 10 mm, 15 mm and 20 mm located under the right shoe of each volunteer. The procedure was performed to capture the dynamic parameters of each participant under five different simulated LLD conditions. Stance time, mean pressure and peak pressure measurements were registered in three trials for each foot and each LLD level. Data were collected during two separate testing sessions, in order to establish intrasession and intersession reliability. The intraclass correlation coefficients (ICCs) for intrasession reliability ranged from 0.775 to 0.983 in the first session and from 0.860 to 0.985 in the second session. The ICCs for intersession reliability ranged from 0.909 to 0.990. Bland-Altman plots showed absence of systematic measurement errors. The results from this study indicate that the Podoprint platform is a reliable system for assessing dynamic parameters under simulated LLD conditions. Future studies should evaluate plantar pressures under LLD conditions, in association with exercise, biomechanics and musculoskeletal disorders.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:1516-3180
1806-9460
1806-9460
DOI:10.1590/1516-3180.2020.0791.R1.110321