Sampling size in the verification of manufactured-supplied air kerma strengths
Quality control mandate that the air kerma strengths (S(K)) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to a...
Saved in:
Published in | Medical physics (Lancaster) Vol. 32; no. 11; p. 3375 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
United States
01.11.2005
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | Quality control mandate that the air kerma strengths (S(K)) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S(K) has a normal distribution. To demonstrate this, the S(K) of each of the seeds measured was corrected to ensure that the average S(K) of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty. |
---|---|
ISSN: | 0094-2405 |
DOI: | 10.1118/1.2089627 |