How reliable and accurate is indocyanine green video angiography in the evaluation of aneurysm obliteration?

Abstract Introduction Indocyanine green video angiography (ICG-VA) has been recently introduced into neurovascular surgery and gained a role in assessing vessel patency and obliteration of intracranial aneurysms (IA) after clipping. Although its correlation with intra-postoperative angiography was d...

Full description

Saved in:
Bibliographic Details
Published inClinical neurology and neurosurgery Vol. 115; no. 7; pp. 870 - 878
Main Authors Özgiray, Erkin, Aktüre, Erinç, Patel, Nirav, Baggott, Christopher, Bozkurt, Melih, Niemann, David, Başkaya, Mustafa K
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.07.2013
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Introduction Indocyanine green video angiography (ICG-VA) has been recently introduced into neurovascular surgery and gained a role in assessing vessel patency and obliteration of intracranial aneurysms (IA) after clipping. Although its correlation with intra-postoperative angiography was demonstrated in previous studies, difficulties in evaluating aneurysm obliteration have not been reported. We report reliability and accuracy of ICG-VA in 109 clipped aneurysms with attention given to five cases in which ICG-VA evaluation resulted in false indication that aneurysms were secure in terms of complete obliteration. Materials and methods A retrospective chart review was performed of IAs surgically treated by a single surgeon from January 2009. In all cases, aneurysm obliteration was confirmed by a combination of microdoppler ultrasonography (MUSG), ICG-VA, and post-operative angiography. Results ICG-VA appropriately assessed vessel patency and aneurysm obliteration in 93.5% of aneurysms clipped. In four cases (3.6%), puncturing the dome of the aneurysm after satisfactory clipping revealed persistent flow within the aneurysm despite ICG-VA showing no flow after clipping. In one case (0.9%), ICG-VA showed persistent flow within the aneurysm and MUSG did not, and puncture of the dome confirmed no flow within the aneurysm. In one case (0.9%), ICG-VA failed to demonstrate residual neck. Conclusion ICG-VA is a simple and safe procedure and an important adjunct to microsurgical clipping of aneurysm. Although ICG-VA assesses vessel patency and obliteration of aneurysms in most cases, applying the principles of microsurgery in aneurysm clipping remains a main tool for obtaining the complete obliteration of aneurysm along with preservation of the normal vasculature.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0303-8467
1872-6968
DOI:10.1016/j.clineuro.2012.08.027