Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?

In this paper, we present a systematic analysis of the relationship between the accuracy of the mapping between EMG and hand kinematics and the control performance in goal-oriented tasks of three simultaneous and proportional myoelectric control algorithms: nonnegative matrix factorization (NMF), li...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on neural systems and rehabilitation engineering Vol. 22; no. 3; pp. 549 - 558
Main Authors Jiang, Ning, Vujaklija, Ivan, Rehbaum, Hubertus, Graimann, Bernhard, Farina, Dario
Format Journal Article
LanguageEnglish
Published United States IEEE 01.05.2014
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this paper, we present a systematic analysis of the relationship between the accuracy of the mapping between EMG and hand kinematics and the control performance in goal-oriented tasks of three simultaneous and proportional myoelectric control algorithms: nonnegative matrix factorization (NMF), linear regression (LR), and artificial neural networks (ANN). The purpose was to investigate the impact of the precision of the kinematics estimation by a myoelectric controller for accurately complete goal-directed tasks. Nine naïve subjects performed a series of goal-directed myoelectric control tasks using the three algorithms, and their online performance was characterized by 6 indexes. The results showed that, although the three algorithms' mapping accuracies were significantly different, their online performance was similar. Moreover, for LR and ANN, the offline performance was not correlated to any of the online performance indexes, and only a weak correlation was found with three of them for NMF . We conclude that for reliable simultaneous and proportional myoelectric control, it is not necessary to achieve high accuracy in the mapping between EMG and kinematics. Rather, good online myoelectric control is achieved by the continuous interaction and adaptation of the user with the myoelectric controller through feedback (visual in the current study). Control signals generated by EMG with rather poor association with kinematic variables can still be fully exploited by the user for precise control. This conclusion explains the possibility of accurate simultaneous and proportional control over multiple degrees of freedom when using unsupervised algorithms, such as NMF.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1534-4320
1558-0210
1558-0210
DOI:10.1109/TNSRE.2013.2287383