Recording low and high spatial frequencies in exit wave reconstructions
Aberration corrected Transmission Electron Microscope (TEM) images can currently resolve information at significantly better than 0.1nm. Aberration corrected imaging conditions seek to optimize the transfer of high-resolution information but in doing so they prevent the transfer of low spatial frequ...
Saved in:
Published in | Ultramicroscopy Vol. 133; pp. 26 - 34 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
01.10.2013
Elsevier |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Aberration corrected Transmission Electron Microscope (TEM) images can currently resolve information at significantly better than 0.1nm. Aberration corrected imaging conditions seek to optimize the transfer of high-resolution information but in doing so they prevent the transfer of low spatial frequency information. To recover low spatial frequency information, aberration corrected images must be acquired at a large defocus which compromises high spatial frequency information transfer. In this paper we present two a posteriori solutions to this problem in which the information bandwidth in an exit wave reconstruction is increased. In the first we reconstruct the electron exit wavefunction from two focal series datasets, with different, uniform focal steps, experimentally demonstrating that the width of the transfer interval can be extended from 0.2nm−1 (∼5nm) to better than 10nm−1 (0.1nm). In the second we outline the use of a focal series recorded with a non-uniform focal step to recover a wider range of spatial frequencies without the need for a large number of images. Using simulated data we show that using this non-uniform focal step the spatial frequency interval for a five image data set may be increased to between 0.25nm−1 (4nm) and 8.3nm−1 (0.12nm) compared to between 0.74nm−1 (1.4nm) and 8.3nm−1 (0.12nm) for the standard focal series geometry.
•We investigate how to optimize focal series acquisition for exit wave restoration.•Non-uniform focal steps extend the range of strong spatial frequency transfer.•A ‘double’ focal series geometry has also been experimentally tested.•This demonstrated good transfer for both high and low spatial frequencies. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0304-3991 1879-2723 |
DOI: | 10.1016/j.ultramic.2013.04.012 |