Evaluation of the Performance of OraQuick Rapid HIV-1/2 Test Among Decedents in Kisumu, Kenya

Estimating cause-related mortality among the dead is not common, yet for clinical and public health purposes, a lot can be learnt from the dead. HIV/AIDS accounted for the third most frequent cause of deaths in Kenya; 39.7 deaths per 100,000 population in 2019. OraQuick Rapid HIV-1/2 has previously...

Full description

Saved in:
Bibliographic Details
Published inJournal of acquired immune deficiency syndromes (1999) Vol. 89; no. 3; p. 282
Main Authors Opollo, Valarie, Nyakeriga, Emmanuel, Kingwara, Leonard, Sila, Alex, Oguta, Macxine, Oyaro, Boaz, Onyango, Dickens, Mboya, Frankline O, Waruru, Anthony, Musingila, Paul, Mwangome, Mary, Nyagah, Lilly M, Ngugi, Catherine, Sava, Solomon, Waruiru, Wanjiru, Young, Peter W, Junghae, Muthoni
Format Journal Article
LanguageEnglish
Published United States 01.03.2022
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Estimating cause-related mortality among the dead is not common, yet for clinical and public health purposes, a lot can be learnt from the dead. HIV/AIDS accounted for the third most frequent cause of deaths in Kenya; 39.7 deaths per 100,000 population in 2019. OraQuick Rapid HIV-1/2 has previously been validated on oral fluid and implemented as a screening assay for HIV self-testing in Kenya among living subjects. We assessed the feasibility and diagnostic accuracy of OraQuick Rapid HIV-1/2 for HIV screening among decedents. Trained morticians collected oral fluid from 132 preembalmed and postembalmed decedents aged >18 months at Jaramogi Oginga Odinga Teaching and Referral Hospital mortuary in western Kenya and tested for HIV using OraQuick Rapid HIV-1/2. Test results were compared with those obtained using the national HIV Testing Services algorithm on matched preembalming whole blood specimens as a gold standard (Determine HIV and First Response HIV 1-2-O). We calculated positive predictive values, negative predictive values, area under the curve, and sensitivity and specificity of OraQuick Rapid HIV-1/2 compared with the national HTS algorithm. OraQuick Rapid HIV-1/2 had similar sensitivity of 92.6% [95% confidence interval (CI): 75.7 to 99.1] on preembalmed and postembalmed samples compared with the gold standard. Specificity was 97.1% (95% CI: 91.9 to 99.4) and 95.2% (95% CI: 89.2 to 98.4) preembalming and postembalming, respectively. Preembalming and postembalming positive predictive value was 89.3% (95% CI: 71.8 to 97.7) and 83.3% (95% CI: 65.3 to 94.4), respectively. The area under the curve preembalming and postembalming was 94.9% (95% CI: 89.6 to 100) and 93.9% (95% CI: 88.5 to 99.4), respectively. The study showed a relatively high-performance sensitivity and specificity of OraQuick Rapid HIV-1/2 test among decedents, similar to those observed among living subjects. OraQuick Rapid HIV-1/2 presents a convenient and less invasive screening test for surveillance of HIV among decedents within a mortuary setting.
ISSN:1944-7884
DOI:10.1097/QAI.0000000000002857