Enhanced real-time ECG coder for packetized telecardiology applications
A new real-time compression method for electrocardiogram (ECG) signals has been developed based on the wavelet transform approach. The method is specifically adaptable for packetized telecardiology applications. The signal is segmented into beats and a beat template is subtracted from them, producin...
Saved in:
Published in | IEEE transactions on information technology in biomedicine Vol. 10; no. 2; pp. 229 - 236 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
IEEE
01.04.2006
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A new real-time compression method for electrocardiogram (ECG) signals has been developed based on the wavelet transform approach. The method is specifically adaptable for packetized telecardiology applications. The signal is segmented into beats and a beat template is subtracted from them, producing a residual signal. Beat templates and residual signals are coded with a wavelet expansion. Compression is achieved by selecting a subset of wavelet coefficients. The number of selected coefficients depends on a threshold which has different definitions depending on the operational mode of the coder. Compression performance has been tested using a subset of ECG records from MIT-BIH Arrhythmia database. This method has been designed for real-time packetized telecardiology scenarios both in wired and wireless environments |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 1089-7771 1558-0032 |
DOI: | 10.1109/TITB.2005.856853 |