Structure of Dietary Measurement Error: Results of the OPEN Biomarker Study

Multiple-day food records or 24-hour dietary recalls (24HRs) are commonly used as “reference” instruments to calibrate food frequency questionnaires (FFQs) and to adjust findings from nutritional epidemiologic studies for measurement error. Correct adjustment requires that the errors in the adopted...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of epidemiology Vol. 158; no. 1; pp. 14 - 21
Main Authors Kipnis, Victor, Subar, Amy F., Midthune, Douglas, Freedman, Laurence S., Ballard-Barbash, Rachel, Troiano, Richard P., Bingham, Sheila, Schoeller, Dale A., Schatzkin, Arthur, Carroll, Raymond J.
Format Journal Article
LanguageEnglish
Published Cary, NC Oxford University Press 01.07.2003
Oxford Publishing Limited (England)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Multiple-day food records or 24-hour dietary recalls (24HRs) are commonly used as “reference” instruments to calibrate food frequency questionnaires (FFQs) and to adjust findings from nutritional epidemiologic studies for measurement error. Correct adjustment requires that the errors in the adopted reference instrument be independent of those in the FFQ and of true intake. The authors report data from the Observing Protein and Energy Nutrition (OPEN) Study, conducted from September 1999 to March 2000, in which valid reference biomarkers for energy (doubly labeled water) and protein (urinary nitrogen), together with a FFQ and 24HR, were observed in 484 healthy volunteers from Montgomery County, Maryland. Accounting for the reference biomarkers, the data suggest that the FFQ leads to severe attenuation in estimated disease relative risks for absolute protein or energy intake (a true relative risk of 2 would appear as 1.1 or smaller). For protein adjusted for energy intake by using either nutrient density or nutrient residuals, the attenuation is less severe (a relative risk of 2 would appear as approximately 1.3), lending weight to the use of energy adjustment. Using the 24HR as a reference instrument can seriously underestimate true attenuation (up to 60% for energy-adjusted protein). Results suggest that the interpretation of findings from FFQ-based epidemiologic studies of diet-disease associations needs to be reevaluated.
Bibliography:istex:76A3B7ABDD0F6D28EB3A99B554EBAB5ECFFAA6BA
Received for publication December 26, 2001; accepted for publication December 3, 2002.