An Evaluation of a New 24-2 Metric for Detecting Early Central Glaucomatous Damage

We sought to test the hypothesis that a recently proposed pattern standard deviation (PSD) metric, based upon the 24-2 visual field (VF) test, as well as the PSD of the 10-2 VF, will miss central glaucomatous damage confirmed with an objective structure-function method. Cross-sectional study. A glau...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of ophthalmology Vol. 223; pp. 119 - 128
Main Authors Hood, Donald C., Thenappan, Abinaya A., Tsamis, Emmanouil, Liebmann, Jeffrey M., De Moraes, C. Gustavo
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.03.2021
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We sought to test the hypothesis that a recently proposed pattern standard deviation (PSD) metric, based upon the 24-2 visual field (VF) test, as well as the PSD of the 10-2 VF, will miss central glaucomatous damage confirmed with an objective structure-function method. Cross-sectional study. A glaucoma (G) group (70 eyes/patients) diagnosed with glaucoma and a 24-2 mean deviation better than −6 dB and a healthy (H) group (45 eyes/patients) had 24-2 and 10-2 VFs and optical coherence tomography (OCT) scans twice within 4 weeks. The PSD(C24-2), based upon the central 12 points of the 24-2, was compared with the PSD(10-2). To evaluate central damage (CD) in G eyes with normal PSD(C24-2) values, a post hoc analysis was combined with a CD reference standard (CD-RS), which was based upon an objective, topographic comparison between abnormal points on the 10-2 VF and OCT probability maps. The 115 PSD(C24-2) and PSD(10-2) values were significantly correlated (Spearman correclation coefficient: rho = 0.55; P < .001) and the number of G eyes (19) identified as abnormal by the PSD(C24-2) was not significantly different from the number (22) identified by the PSD(10-2) (P = .15). However, based upon the CD-RS, 44 of 70 G eyes were classified as abnormal. The PSD(C24-2) missed 27 (61%) of these 44 eyes, and the PSD(10-2) missed 23 (52%) of these eyes. Post hoc analysis revealed clear CD in most of these eyes. Neither the PSD(C24-2) nor the PSD(10-2) metric is good measure of early CD. Instead we recommend a topographic approach based upon OCT probability maps and a 10-2 VF.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9394
1879-1891
DOI:10.1016/j.ajo.2020.07.045