Development and validation of SARMs and metabolic modulators screening in hair using UHPLC-MS/MS: Application to a doping case and first identification of S23 in authentic human hair

•Development and validation of a rapid method for SARMs in hair using UHPLC-MS/MS.•Simultaneous analysis of 9 SARMs and 2 metabolic modulators in hair.•First identification of S23 in authentic human hair in a doping case. Selective Androgen Receptors Modulators (SARMs) are a new class of doping drug...

Full description

Saved in:
Bibliographic Details
Published inJournal of chromatography. B, Analytical technologies in the biomedical and life sciences Vol. 1187; p. 123048
Main Authors Gheddar, Laurie, Raul, Jean-Sébastien, Kintz, Pascal
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 15.12.2021
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•Development and validation of a rapid method for SARMs in hair using UHPLC-MS/MS.•Simultaneous analysis of 9 SARMs and 2 metabolic modulators in hair.•First identification of S23 in authentic human hair in a doping case. Selective Androgen Receptors Modulators (SARMs) are a new class of doping drugs that emerged in sport since 2008. Easy access on the Internet also leads to their misuse by amateurs. It seems important for a laboratory of toxicology to develop a targeted screening of SARMs, given their health risks. A method has been developed and validated for the analysis in hair of 9 SARMs (AC262536, ACP-105, andarine, LGD-4033, MK-0773, MK 677, ostarine, RAD 410 and S23) and 2 other metabolic modulators (GW501516, SR9009), using liquid chromatography coupled to tandem mass spectrometry. After addition of bicalutamide-D4 used as internal standard and incubation in phosphate buffer pH = 9.5, 20 mg of hair samples were extracted with liquid/liquid extraction. Linearity was verified for all compounds between 0.5 and 50 and 2000 pg/mg. LOD and LOQ were determined between 0.1–20 and 0.5–50 pg/mg respectively, according to the various analytes. Intra- and inter-day precision (CV < 20%), matrix effects and recovery were evaluated for all compounds with CVs < 20%. The application and the interest of SARMs screening was demonstrated in a doping case. Three SARMs were detected namely andarine (120–1644 pg/mg), ostarine (1–9 pg/mg) and S23 (0.6–16 pg/mg) in 6x1 cm segments of the subject.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1570-0232
1873-376X
1873-376X
DOI:10.1016/j.jchromb.2021.123048