Quantitative lung perfusion blood volume using dual energy CT–based effective atomic number (Zeff) imaging

Background Iodine material images (aka iodine basis images) generated from dual energy computed tomography (DECT) have been used to assess potential perfusion defects in the pulmonary parenchyma. However, iodine material images do not provide the needed absolute quantification of the pulmonary blood...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 48; no. 11; pp. 6658 - 6672
Main Authors Li, Ke, Li, Yinsheng, Qi, Zhihua, Garrett, John W., Grist, Thomas M., Chen, Guang‐Hong
Format Journal Article
LanguageEnglish
Published United States 01.11.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Iodine material images (aka iodine basis images) generated from dual energy computed tomography (DECT) have been used to assess potential perfusion defects in the pulmonary parenchyma. However, iodine material images do not provide the needed absolute quantification of the pulmonary blood pool, as materials with effective atomic numbers (Zeff) different from those of basis materials may also contribute to iodine material images, thus confounding the quantification of perfusion defects. Purpose (i) To demonstrate the limitations of iodine material images in pulmonary perfusion defect quantification and (ii) to develop and validate a new quantitative biomarker using effective atomic numbers derived from DECT images. Methods The quantitative relationship between the perfusion blood volume (PBV) in pulmonary parenchyma and the effective atomic number (Zeff) spatial distribution was studied to show that the desired quantitative PBV maps are determined by the spatial maps of Zeff as PBVZeff(x)=aZeffβ(x)+b, where a, b, and β are three constants. Namely, quantitative PBVZeff is determined by Zeff images instead of the iodine basis images. Perfusion maps were generated for four human subjects to demonstrate the differences between conventional iodine material image‐based PBV (PBViodine) derived from two‐material decompositions and the proposed PBVZeff method. Results Among patients with pulmonary emboli, the proposed PBVZeff maps clearly show the perfusion defects while the PBViodine maps do not. Additionally, when there are no perfusion defects present in the derived PBV maps, no pulmonary emboli were diagnosed by an experienced thoracic radiologist. Conclusion Effective atomic number–based quantitative PBV maps provide the needed sensitive and specific biomarker to quantify pulmonary perfusion defects.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0094-2405
2473-4209
2473-4209
DOI:10.1002/mp.15227