Conservative initial postoperative anticoagulation strategy after HeartMate 3 left ventricular assist device implantation

Introduction Although anticoagulation therapy is mandated after implantation of a left ventricular assist device (LVAD), postoperative bleedings and reoperations occur relatively frequently and are associated with worse outcomes. We evaluated the use of a conservative postoperative anticoagulation p...

Full description

Saved in:
Bibliographic Details
Published inNetherlands heart journal Vol. 30; no. 10; pp. 466 - 472
Main Authors Damman, Kevin, van den Broek, Stan A. J., Mecozzi, Gianclaudio, Droogh, Joep M., Metz, Ethel, Oude Lansink, Annemieke, Krikken, Jan A., Erasmus, Michiel E., Kuijpers, Michiel
Format Journal Article
LanguageEnglish
Published Houten Bohn Stafleu van Loghum 01.10.2022
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Introduction Although anticoagulation therapy is mandated after implantation of a left ventricular assist device (LVAD), postoperative bleedings and reoperations occur relatively frequently and are associated with worse outcomes. We evaluated the use of a conservative postoperative anticoagulation protocol in patients implanted with a HeartMate 3 (HM3) LVAD. Methods In a single-centre retrospective analysis of postoperative outcomes after HM3 LVAD implantation, a standard (old) anticoagulation protocol (i.e. early, full-dose anticoagulation with low-molecular weight heparin and overlapping vitamin K antagonist) was compared with a new conservative anticoagulation protocol (i.e. slow initiation of vitamin K antagonists without overlapping heparin). Main outcomes were changes in international normalised ratio (INR), lactate dehydrogenase (LDH), bleeding and/or tamponade events requiring reoperation, length of stay and adverse events. Results In total, 73 patients (48 in old vs 25 in new protocol group) were evaluated. Mean age was 56 years (standard deviation 13) and most patients (78%) were males. Changes in INR and LDH in the first 14 days were similar in both groups ( p  = 0.50 and p  = 0.997 for interaction, respectively). Number of bleeding/tamponade events requiring reoperation was lower in the new than in the old protocol group (4% vs 33%, p  = 0.005). Postoperative 30-day mortality was similar, and we observed no thromboembolic events. Median (25th–75th percentiles) total length of postoperative hospital stay (27 (25–41) vs 21 (19–27) days, p  < 0.001) and length of intensive care unit stay (5 (2–9) vs 2 (2–5) days, p  = 0.022) were significantly shorter in the new protocol group. Conclusion These retrospective data suggest that conservative slow initiation of anticoagulation therapy after HM3 LVAD implantation is associated with less bleeding/tamponade events requiring reoperation, a similar safety profile and a shorter duration of stay than the currently advised standard anticoagulation protocol.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1568-5888
1876-6250
DOI:10.1007/s12471-022-01671-1