Direct comparison of the reproducibility of in-office and self-measured home blood pressures

The aim was to compare short-term and long-term reproducibilities of in-office unattended blood pressure (BP), namely automated office blood pressure (AOBP), conventionally measured attended office BP, and self-measured home BP. A multicentre, clinical study was conducted in Japan, and 287 Japanese...

Full description

Saved in:
Bibliographic Details
Published inJournal of hypertension Vol. 40; no. 2; p. 398
Main Authors Asayama, Kei, Ohkubo, Takayoshi, Rakugi, Hiromi, Miyakawa, Masaaki, Mori, Hisao, Katsuya, Tomohiro, Ikehara, Yumi, Ueda, Shinichiro, Ohya, Yusuke, Tsuchihashi, Takuya, Kario, Kazuomi, Miura, Katsuyuki, Ito, Sadayoshi, Umemura, Satoshi
Format Journal Article
LanguageEnglish
Published Netherlands 01.02.2022
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:The aim was to compare short-term and long-term reproducibilities of in-office unattended blood pressure (BP), namely automated office blood pressure (AOBP), conventionally measured attended office BP, and self-measured home BP. A multicentre, clinical study was conducted in Japan, and 287 Japanese outpatients on antihypertensive drug medication were followed-up for 1 year. The intensity of drug treatment was sustained consistently throughout the study period (defined daily doses, 1.62-1.68; P = 0.12). The mean SBP differences between baseline and 1 month later, as well as baseline and 1 year later, were less than 1.5 mmHg, whereas the standard deviations of the differences for home, AOBP, and attended office measurements for the 1-year interval were 7.7, 14.5, and 15.3 mmHg, respectively. The coefficients of variation were significantly smaller for home BP than for AOBP among all patients at both 1-month and 1-year intervals (P < 0.0001). In the 1-month interval, partial correlation coefficients of home BP (r, 0.73/0.88 for systolic/diastolic measures) were significantly higher than of conventional BP (r, 0.47/0.69). However, the correlations converged to the modest level regardless of BP information (r, 0.49-0.54/0.63-0.73) when the 1-year interval was assessed. Results were confirmatory when patients on the same drug regimen (n = 167) were analysed. A higher reproducibility of home BP was demonstrated compared with in-office BP, including AOBP. However, the modest correlations for the 1-year interval support the importance of regular assessment of BP, regardless of in-office or home measurements for treatment of hypertension.
ISSN:1473-5598
DOI:10.1097/hjh.0000000000003026