Motion Resistant Image-Photoplethysmography Based on Spectral Peak Tracking Algorithm

Medical fields have seen increasing attention being given to image based heart rate measurement in recent years. One of the major limitations is motion artifacts of subject's head. Although there have been many studies focusing on signal extraction using different parameters and models, the dev...

Full description

Saved in:
Bibliographic Details
Published inIEEE access Vol. 6; pp. 21621 - 21634
Main Authors Wu, Bing-Fei, Huang, Po-Wei, Lin, Chun-Hsien, Chung, Meng-Liang, Tsou, Tsong-Yang, Wu, Yu-Liang
Format Journal Article
LanguageEnglish
Published Piscataway IEEE 01.01.2018
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Medical fields have seen increasing attention being given to image based heart rate measurement in recent years. One of the major limitations is motion artifacts of subject's head. Although there have been many studies focusing on signal extraction using different parameters and models, the development of frequency domain analysis is emerging slowly and moving in many directions. In the field of contact photoplethysmography (PPG), recent studies employed the acceleration signals to assist their spectral peak tracking algorithms. Inspired by the development of contact PPG, we are proposing a motion resistant spectral peak tracking (MRSPT) framework which eliminates the motion artifacts by integrating facial motion signals. The effectiveness of MRSPT coupled with the optimal image-based PPG (iPPG) signal has been tested against the state-of-the-art spectral peak tracking algorithms, multi-channel spectral matrix decomposition (MC-SMD), and the maximum peak selection coupled with optimal iPPG signal (Optimal MPS). Compared with MC-SMD and Optimal MPS, MRSPT uplifts the success rate-10 (success rate-5), the probability in which the absolute error is below ten (five) beats per mins, from 54.7% (36.3%) with MC-SMD and 73.0% (61.3%) with Optimal MPS to 90.7% (75.7%) with MRSPT in motion scenarios where subject moves arbitrarily with different distance or lighting. MRSPT also enhances the success rate-10 (success rate-5) from 40.7% (26.3%) with MC-SMD and 57.4% (45.7%) with Optimal MPS to 73.4% (58.4%) with MRSPT in all seven motion conditions including driving and running. Averagely, the success rate-five of Optimal MRSPT surpass the success rate-10 of both Optimal MPS and MC-SMD.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:2169-3536
2169-3536
DOI:10.1109/ACCESS.2018.2828133