Precision and Normative Values of a New Computerized Chart for Contrast Sensitivity Testing

The purpose was to define a normative database for a grating test for contrast sensitivity, based on a chart monitor with high-definition liquid crystal display, and validate its measurements by assessing their repeatability and determining responsiveness to cataract surgery. Three samples were anal...

Full description

Saved in:
Bibliographic Details
Published inScientific reports Vol. 9; no. 1; pp. 16537 - 6
Main Authors Savini, Giacomo, Calossi, Antonio, Schiano-Lomoriello, Domenico, Barboni, Piero
Format Journal Article
LanguageEnglish
Published London Nature Publishing Group UK 12.11.2019
Nature Publishing Group
Subjects
Online AccessGet full text
ISSN2045-2322
2045-2322
DOI10.1038/s41598-019-52987-9

Cover

Loading…
More Information
Summary:The purpose was to define a normative database for a grating test for contrast sensitivity, based on a chart monitor with high-definition liquid crystal display, and validate its measurements by assessing their repeatability and determining responsiveness to cataract surgery. Three samples were analyzed: (1) healthy volunteers to assess the repeatability of measurements, (2) healthy subjects to develop the normative database, (3) patients undergoing cataract surgery. All subjects were tested with the grating contrast sensitivity test (Vision Chart, CSO) at 1.5, 3, 6, 12 and 18 cycles per degree. The instrument software progressively reduces the contrast of the gratings according to the Quick Estimate by Sequential Testing (QUEST) procedure. In the subjects of the first sample, three consecutive measurements were taken and repeatability was assessed on the basis of the intra-session test-retest variability and the coefficient of variation. The test offered high repeatability, with test-retest variability ranging between 0.05 and 0.23 Log CS and the coefficient of variation between 0.61 and 4.21%. Normative data did not show a normal distribution. The highest median values were observed at 1.5, 3 and 6 cycles per degree frequencies. At these frequencies a ceiling effect was evident. In cataract patients, postoperative values showed an improvement at all spatial frequencies. In conclusion, the new contrast sensitivity test provides repeatable measurements that can be used for clinical purposes. In patients with healthy eyes and good vision, attention has to be paid to the ceiling effect.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-019-52987-9