Three-Dimensional Speckle Tracking Echocardiography Allows Detailed Evaluation of Left Atrial Function in Hypertrophic Cardiomyopathy-Insights from the MAGYAR-Path Study

Introduction Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three‐dimensional (3D) speckle tracking echocardiography (STE) has just been int...

Full description

Saved in:
Bibliographic Details
Published inEchocardiography (Mount Kisco, N.Y.) Vol. 31; no. 10; pp. 1245 - 1252
Main Authors Domsik, Péter, Kalapos, Anita, Chadaide, Számi, Sepp, Róbert, Hausinger, Péter, Forster, Tamás, Nemes, Attila
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.11.2014
Subjects
Online AccessGet full text
ISSN0742-2822
1540-8175
1540-8175
DOI10.1111/echo.12568

Cover

Loading…
More Information
Summary:Introduction Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three‐dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE‐derived LA volumetric and strain parameters in HCM with healthy controls. Methods The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age‐ and gender‐matched healthy controls. Complete two‐dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Results Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P < 0.0001) and minimum (39.2 ± 19.1 vs. 16.0 ± 4.6 mL, P < 0.0001) volumes and LA volume before atrial contraction (53.6 ± 19.9 vs. 24.0 ± 6.2 mL, P < 0.0001) were significantly increased in HCM patients. Atrial stroke volumes respecting cardiac cycles proved to be increased, while emptying fractions were decreased in subjects with HCM. Mean global radial (−12.2 ± 6.7% vs. −19.6 ± 11.7, P < 0.05), longitudinal (26.5 ± 16.5% vs. 29.8 ± 12.1%, P < 0.05) and 3D strain (−6.1 ± 4.4% vs. −12.5 ± 10.2%, P < 0.05) proved to be significantly reduced in HCM patients as compared with matched controls. Conclusions Three‐dimensional speckle tracking echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements.
Bibliography:ArticleID:ECHO12568
istex:4890E5A149CEF55CA285FD22EE063D983DA82CE3
ark:/67375/WNG-4NQHMPQB-T
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
ISSN:0742-2822
1540-8175
1540-8175
DOI:10.1111/echo.12568