Nano-indentation testing of new and fractured nickel-titanium endodontic instruments

Jamleh A, Sadr A, Nomura N, Yahata Y, Ebihara A, Hanawa T, Tagami J, Suda H. Nano‐indentation testing of new and fractured nickel‐titanium endodontic instruments. International Endodontic Journal, 45, 462–468, 2012. Aim  To investigate the effect of cyclic fatigue on nickel‐titanium (NiTi) endodonti...

Full description

Saved in:
Bibliographic Details
Published inInternational endodontic journal Vol. 45; no. 5; pp. 462 - 468
Main Authors Jamleh, A., Sadr, A., Nomura, N., Yahata, Y., Ebihara, A., Hanawa, T., Tagami, J., Suda, H.
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.05.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Jamleh A, Sadr A, Nomura N, Yahata Y, Ebihara A, Hanawa T, Tagami J, Suda H. Nano‐indentation testing of new and fractured nickel‐titanium endodontic instruments. International Endodontic Journal, 45, 462–468, 2012. Aim  To investigate the effect of cyclic fatigue on nickel‐titanium (NiTi) endodontic instruments using a nano‐indentation test. Methodology  Eight ProFile NiTi rotary instruments (size 30, taper 0.06; Dentsply Maillefer, Ballaigues, Switzerland) were tested using a cyclic fatigue set‐up until fracture. The fractured instruments and eight new NiTi instruments of the same size and taper were used for a nano‐indentation test on the internal surfaces of a NiTi instruments in the region just adjacent to their fractured edge (group I) and in the same region of the new group (group II), and the cutting part beside the shaft for both instruments [group III (fractured) and group IV (new)]. Data were statistically analyzed using one‐way analysis of variance and Games–Howell post hoc test. The alpha‐type error was set at 0.05. Results  Significant differences in terms of hardness and elastic modulus for each group (P < 0.05) were found, with group I having the lowest mean values followed by group III. Additionally, standard deviations increased remarkably after failure, as represented by groups I and III. Conclusion  The nano‐indentation technique can be applied to determine the performance and the failure mechanism of NiTi instruments. The fatigue process revealed a significant decrease in the hardness and elastic modulus of the NiTi instrument. As indicated by the low hardness, the fatigue process did not result in work hardening but rather work softening.
Bibliography:ark:/67375/WNG-BMJ2FK1F-J
ArticleID:IEJ1997
istex:3D68A6E4C9552B03A5CDC6B13A250D029155204C
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0143-2885
1365-2591
DOI:10.1111/j.1365-2591.2011.01997.x