Comparison of continuous-wave, chop-wave, and super pulse laser wounds

Some of the latest generation of CO2 lasers incorporate features that alter the wave form. The present study was undertaken to evaluate the relative zone of coagulation in acute laser wounds created in continuous-wave (CW), chop-wave (CPW), and super pulse wave (SPW) modes. The damage from single-po...

Full description

Saved in:
Bibliographic Details
Published inLasers in surgery and medicine Vol. 8; no. 2; p. 119
Main Authors Lanzafame, R J, Naim, J O, Rogers, D W, Hinshaw, J R
Format Journal Article
LanguageEnglish
Published United States 1988
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Some of the latest generation of CO2 lasers incorporate features that alter the wave form. The present study was undertaken to evaluate the relative zone of coagulation in acute laser wounds created in continuous-wave (CW), chop-wave (CPW), and super pulse wave (SPW) modes. The damage from single-point impact sites and incisions was compared in a guinea pig model. Animals were anesthetized with pentobarbital, and wounds were created with a 125-mm handpiece in focus (0.2-mm spot size) on dorsal and flank skin sites with the Sharplan 743 and 1100 CO2 lasers (Sharplan, Ltd., Allendale, NJ). Point impacts of CW and CPW were compared at power levels of 5, 10, 25, 40, 60, and 80 W at time durations of 0.05, 0.1, 0.2, and 0.5 seconds. Incisions of 3.0 cm were created at 25 W in CW, CPW, and SPW modes. Histologic sections stained with hematoxylin and eosin and Van Giesen elastin stains were evaluated by a single observer (R.J.L.). Zones of coagulation for the point-impact study varied from 79 to 257 +/- 66 (SD) micron in width with no significant differences between any of the wounds. Greater thermal damage (coagulation) occurred as the time interval increased. The zones of coagulation in the incision study were 309 +/- 83 (SD) micron for CW, 238 +/- 51 (SD) micron for SPW1 (743), 260 +/- 79 (SD) micron for CPW, and 194 +/- 56 (SD) micron for SPW2 (1100). These results are significant to the P less than 0.01 level.
ISSN:0196-8092
DOI:10.1002/lsm.1900080205