Improvement of Control Method for Fixed Energy Storage System

A new control method was developed, which ensures that an adequate constant power is supplied to electric rolling stock, while a storage unit is kept at a middle state of charge for subsequent powering or regenerating phases. A prototype storage system, applying the developed control method and empl...

Full description

Saved in:
Bibliographic Details
Published inQuarterly Report of RTRI Vol. 55; no. 2; pp. 79 - 85
Main Authors KONISHI, Takeshi, YOSHII, Tsurugi, SHIGEEDA, Hidenori
Format Journal Article
LanguageEnglish
Published Tokyo Railway Technical Research Institute 2014
Japan Science and Technology Agency
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A new control method was developed, which ensures that an adequate constant power is supplied to electric rolling stock, while a storage unit is kept at a middle state of charge for subsequent powering or regenerating phases. A prototype storage system, applying the developed control method and employing electric double layer capacitors (EDLCs) as the storage unit, was built. Tests were performed using a railway test line and electric rolling stock, and it was confirmed that the system could charge or discharge according to powering/regenerating of electric rolling stock.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0033-9008
1880-1765