Improvement of Control Method for Fixed Energy Storage System
A new control method was developed, which ensures that an adequate constant power is supplied to electric rolling stock, while a storage unit is kept at a middle state of charge for subsequent powering or regenerating phases. A prototype storage system, applying the developed control method and empl...
Saved in:
Published in | Quarterly Report of RTRI Vol. 55; no. 2; pp. 79 - 85 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Tokyo
Railway Technical Research Institute
2014
Japan Science and Technology Agency |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A new control method was developed, which ensures that an adequate constant power is supplied to electric rolling stock, while a storage unit is kept at a middle state of charge for subsequent powering or regenerating phases. A prototype storage system, applying the developed control method and employing electric double layer capacitors (EDLCs) as the storage unit, was built. Tests were performed using a railway test line and electric rolling stock, and it was confirmed that the system could charge or discharge according to powering/regenerating of electric rolling stock. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0033-9008 1880-1765 |
DOI: | 10.2219/rtriqr.55.79 |