Metabolic and hormonal responses to subcutaneous glucagon in healthy beagles

Objective To compare the effects of subcutaneous (SC) and intravenous (IV) glucagon on glucose concentrations, and insulin and cortisol secretion. Design Prospective randomized 3‐way crossover study. Setting University teaching hospital. Animals Five healthy beagles. Interventions Diabetes mellitus...

Full description

Saved in:
Bibliographic Details
Published inJournal of veterinary emergency and critical care (San Antonio, Tex. : 2000) Vol. 22; no. 5; pp. 558 - 563
Main Authors Zeugswetter, Florian K., Schornsteiner, Elisa, Haimel, Georg, Schwendenwein, Ilse
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.10.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective To compare the effects of subcutaneous (SC) and intravenous (IV) glucagon on glucose concentrations, and insulin and cortisol secretion. Design Prospective randomized 3‐way crossover study. Setting University teaching hospital. Animals Five healthy beagles. Interventions Diabetes mellitus and adrenal insufficiency were excluded by repeated glucose and fructosamine measurements, urinalysis, abdominal ultrasonography, and ACTH stimulation tests. Blood samples were collected before and after the SC and IV injection of 1 milligram (1 mg = 1 mL) commercially available synthetic glucagon and analyzed for insulin‐like immunoreactivity (insulin‐imr), glucose, ACTH and cortisol concentrations. The results were compared with those obtained after the SC injection of 1 mL saline (placebo). Measurements were performed over a period of up to 3 hours. Measurements and Main Results SC glucagon significantly increased glucose and insulin‐imr (P < 0.001 and 0.043, respectively). Peak glucose concentrations were observed after 20 minutes and were lower than after IV injection (mean ± SD: 6.5 ± 1.1 mmol/L versus 9.3 ± 0.8 mmol/L [117.1 ± 19.8 mg/dL versus 167.6 ± 14.4 mg/dL]; P = 0.001). The route of application had no significant effect on insulin‐imr (peak concentration: median [range]: 83.3 [13.9–312.5] pmol/L versus 194.5 [118.1–284.7] pmol/L [12 [2–45] μU/mL versus 28 [17–41] μU/mL; P = 0.151). SC glucagon did not increase cortisol or ACTH concentrations at any time point of observation (P > 0.05). Aside from somnolence, no adverse events were recorded. Conclusions SC glucagon has the potential to be used as a simple and safe test in diabetic animals, but is of little use in animals with suspected corticotrophic insufficiency. The hyperglycemic effects are significant, implying that the commercially available human emergency kit could be useful in the home treatment of canine hypoglycemic emergencies.
Bibliography:istex:1141C6F1E14927D06294EDF7B17F64FE577404A0
ArticleID:VEC793
ark:/67375/WNG-S5DF643H-Z
The authors declare no conflicts of interests.
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:1479-3261
1476-4431
DOI:10.1111/j.1476-4431.2012.00793.x