Value of Regular Defibrillation Threshold Testing After Extracardiac Implantable Cardioverter Defibrillator Placement in Small Children During Mid-Term Follow-Up

The purpose of this study was to analyze course of defibrillation threshold (DFT) with growth. Data on regular DFT testing after extracardiac implantable cardioverter-defibrillator (ICD) placement in infants and small children is still limited. An extracardiac ICD was placed in 23 pediatric patients...

Full description

Saved in:
Bibliographic Details
Published inJACC. Clinical electrophysiology Vol. 4; no. 7; pp. 936 - 943
Main Authors Kriebel, Thomas, Müller, Matthias J., Ruschewski, Wolfgang, Krause, Ulrich, Paul, Thomas, Schneider, Heike
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.07.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The purpose of this study was to analyze course of defibrillation threshold (DFT) with growth. Data on regular DFT testing after extracardiac implantable cardioverter-defibrillator (ICD) placement in infants and small children is still limited. An extracardiac ICD was placed in 23 pediatric patients (median age 6.1 years; median body weight 21 kg, median length 120 cm). The defibrillator lead was tunneled pleurally, and the device was placed as “active can” in the right upper abdomen or in a horizontal position between the diaphragm and the pericardium, respectively. DFT was verified intraoperatively, 3 months later, and every 12 months thereafter. The aim was to achieve DFT <15 J allowing ICD programming with a double safety margin above DFT. In all 23 patients, an intraoperative DFT <15 J could be accomplished. Serial DFT testing showed an increase from a median DFT of 10 J intraoperatively to 15 J after 1 year. During mean follow-up of 2.0 years, a significant correlation between DFT and body length, but not body weight, was observed. In 4 of 23 (17%) patients, surgical revision was required because of a DFT increase >20 J during regular DFT testing. No complications regarding DFT testing were noted. After extracardiac ICD placement in infants and small children, DFT increase related to body length was evident during mid-term follow-up. Routine serial DFT testing was a safe procedure and identified a significant DFT increase in 4 of 23 patients. Serial DFT testing during follow-up in these patients is recommended. [Display omitted]
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2405-500X
2405-5018
DOI:10.1016/j.jacep.2018.03.012