Restenosis of Endovascular Stents From Stent Compression

Objectives. We sought to determine the basis for restenosis within superficial femoral arteries (SFAs) and hemodialysis conduits treated with balloon-expandable stents. Background. Use of stents within coronary and peripheral vessels continues to increase exponentially. The mechanism of restenosis w...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American College of Cardiology Vol. 29; no. 2; pp. 328 - 338
Main Authors Rosenfield, Kenneth, Schainfeld, Robert, Pieczek, Ann, Haley, Laura, Isner, Jeffrey M
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.02.1997
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives. We sought to determine the basis for restenosis within superficial femoral arteries (SFAs) and hemodialysis conduits treated with balloon-expandable stents. Background. Use of stents within coronary and peripheral vessels continues to increase exponentially. The mechanism of restenosis within stents placed at various vascular sites is not well understood. In particular, the implications of deploying a balloon-expandable stent in a compressible site are not well understood. Methods. After the serendipitous detection of stent deformation during intravascular ultrasound (IVUS) examination of a restenosed dialysis fistula, we evaluated a consecutive series of patients with stents placed in compressible vascular sites, including the SFA (six patients) and hemodialysis fistulae (five patients). Clinical, angiographic and IVUS examinations were performed to evaluate mechanisms of restenosis. Results. Stent compression was identified as the principal cause of restenosis in all dialysis conduits and SFAs. Stent deformity was not reliably identified by angiography; however, IVUS identified compression of two forms: eccentric deformation, implicating two-point compressive force, and complete circumferential encroachment of stent struts around the catheter, suggesting multidirectional compressive force. Despite redilation, secondary restenosis resulting from recurrent compression recurred in most sites. Conclusions. Restenosis within balloon-expandable endovascular stents may occur as a result of stent compression, a phenomenon readily detected by IVUS, but often not by angiography. These findings have significant implications for the use of balloon-expandable stents within vascular sites subject to extrinsic compression, such as hemodialysis conduits, the adductor canal segment of the SFA and carotid arteries. (J Am Coll Cardiol 1997;29:328–38)
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0735-1097
1558-3597
DOI:10.1016/S0735-1097(96)00498-6