Impact of mechanical ventilation control strategies based on non-steady-state and steady-state Wells-Riley models on airborne transmission and building energy consumption

Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission. Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate, which may lead to high energy consumption. The Wells-Riley (WR) model...

Full description

Saved in:
Bibliographic Details
Published inJournal of Central South University Vol. 29; no. 7; pp. 2415 - 2430
Main Authors Sha, Hao-han, Zhang, Xin, Qi, Da-hai
Format Journal Article
LanguageEnglish
Published Changsha Central South University 2022
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission. Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate, which may lead to high energy consumption. The Wells-Riley (WR) model is widely used to predict infection risk and control the ventilation rate. However, few studies compared the non-steady-state (NSS) and steady-state (SS) WR models that are used for ventilation control. To fill in this research gap, this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption. The modified NSS/SS WR models were proposed by considering many parameters that were ignored before, such as the initial quantum concentration. Based on the NSS/SS WR models, two new ventilation control strategies were proposed. A real building in Canada is used as the case study. The results indicate that under a high initial quantum concentration (e.g., 0.3 q/m 3 ) and no protective measures, SS WR control underestimates the required ventilation rate. The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2095-2899
2227-5223
2227-5223
DOI:10.1007/s11771-022-5072-z