Reduction of AF Recurrence After Pulmonary Vein Isolation by Eliminating ATP-Induced Transient Venous Re-Conduction

Background: Recent evidence has suggested that the transient re‐conduction of the isolated pulmonary vein (PV) induced by the intravenous injection of adenosine (dormant PV conduction) might predict the incidence of subsequent venous reconnection after the procedure, which is the main cause of the a...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular electrophysiology Vol. 18; no. 7; pp. 704 - 708
Main Authors MATSUO, SEIICHIRO, YAMANE, TEIICHI, DATE, TARO, INADA, KEIICHI, KANZAKI, YASUKO, TOKUDA, MICHIFUMI, SHIBAYAMA, KENRI, MIYANAGA, SATORU, MIYAZAKI, HIDEKAZU, SUGIMOTO, KENICHI, MOCHIZUKI, SEIBU
Format Journal Article
LanguageEnglish
Published Malden, USA Blackwell Publishing Inc 01.07.2007
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background: Recent evidence has suggested that the transient re‐conduction of the isolated pulmonary vein (PV) induced by the intravenous injection of adenosine (dormant PV conduction) might predict the incidence of subsequent venous reconnection after the procedure, which is the main cause of the atrial fibrillation (AF) recurrence after PV isolation (PVI). We tested the hypothesis that the elimination of these dormant PV conductions by additional radiofrequency (RF) applications can improve the efficacy of the PVI. Methods and Results: One hundred forty‐eight patients (124 males; mean age 53 ± 9 years) with drug‐refractory AF underwent the PVI procedure. The standard PVI was performed in 94 patients (Group A), whereas the elimination of adenosine triphosphate (ATP)‐induced dormant conduction using additional RF energy was performed in addition to the standard PVI in other 54 patients (Group B). Dormant conduction was observed in 56% of the patients (30/54) in Group B and 95% of these transient re‐conductions were successfully eliminated by additional RF applications (mean: 1.5 ± 1.0 times). During the mean follow‐up period of 20 months, recurrences of AF after the procedures were observed significantly less frequently in Group B (20%) than in Group A (40%) (P < 0.05). Conclusion: The use of additional RF applications to eliminate transient PV reconnection induced by ATP injection led to a reduction of AF recurrence after PVI, most likely due to the minimization of the subsequent PV reconnection.
Bibliography:ArticleID:JCE842
istex:7863F31F6784A864BFAA08C20CA842109F216D23
ark:/67375/WNG-TJX267H2-V
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1045-3873
1540-8167
DOI:10.1111/j.1540-8167.2007.00842.x