Optimal fast T2-weighted magnetic resonance microscopy imaging of the eye and its clinical application

Purpose: To compare a half‐Fourier single‐shot rapid acquisition with relaxation enhancement (RARE) sequence with a balanced steady‐state free precession (b‐SSFP) sequence in the evaluation of the eye using magnetic resonance (MR) microscopy imaging and to clarify the usefulness of RARE microscopy i...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 31; no. 5; pp. 1210 - 1214
Main Authors Tanitame, Keizo, Sasaki, Ko, Sone, Takashi, Otani, Keiko
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.05.2010
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose: To compare a half‐Fourier single‐shot rapid acquisition with relaxation enhancement (RARE) sequence with a balanced steady‐state free precession (b‐SSFP) sequence in the evaluation of the eye using magnetic resonance (MR) microscopy imaging and to clarify the usefulness of RARE microscopy imaging in evaluating nonoperative glaucoma patients and patients who have undergone surgery for glaucoma or cataract. Materials and Methods: One‐mm and 2‐mm slice thickness images of RARE sequence and b‐SSFP sequence using a 1.5 T MR unit and a 23‐mm microscopy coil were obtained in eight healthy volunteers. The signal‐to‐noise (S/N) ratio of aqueous humor in the anterior chamber was measured quantitatively and visualization of the anterior chamber anatomy was assessed qualitatively. Furthermore, we evaluated 21 glaucoma patients (including six postoperative patients) and four patients after cataract surgery with 2‐mm slice thickness RARE MRI. Results: The 2‐mm slice thickness RARE imaging had a significantly greater S/N ratio than the 1‐mm slice thickness RARE imaging (P < 0.05) and acquired the best image quality among the four types of images (P < 0.01). Additionally, 2‐mm slice thickness RARE microscopy imaging could depict anterior chamber anatomy of glaucoma eyes and eyes after cataract surgery. Conclusion: We believe that optimal fast T2‐weighted MR microimaging might become a useful ophthalmologic examination technique. J. Magn. Reson. Imaging 2010;31:1210–1214. ©2010 Wiley‐Liss, Inc.
Bibliography:ArticleID:JMRI22165
istex:EF70C928BC4D7FB70902866965C9EF7E36A8CC6D
ark:/67375/WNG-42VP07NL-6
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.22165