Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of radiology Vol. 81; no. 8; pp. 1712 - 1716
Main Authors Xu, Yonghua, Cai, Wenli, Nappi, Janne, Yoshida, Hiro
Format Journal Article
LanguageEnglish
Published Ireland Elsevier Ireland Ltd 01.08.2012
Subjects
Online AccessGet full text
ISSN0720-048X
1872-7727
1872-7727
DOI10.1016/j.ejrad.2011.04.051

Cover

Loading…
More Information
Summary:To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p<0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4mm increased to 84% (31/37). The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0720-048X
1872-7727
1872-7727
DOI:10.1016/j.ejrad.2011.04.051