Posterior Iris Fixation of the Iris-Claw Intraocular Lens Implantation through a Scleral Tunnel Incision

Purpose To evaluate the technique, efficacy, and safety of posterior iris fixation of iris-claw intraocular lens (IOLs) implantation through a scleral tunnel incision for aphakia correction. Design Noncomparative, interventional case series. Methods A secondary posterior iris fixation of the Artisan...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of ophthalmology Vol. 144; no. 4; pp. 586 - 591.e2
Main Authors Baykara, Mehmet, Ozcetin, Hikmet, Yilmaz, Sami, Timuçin, Özgur Bülent
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.10.2007
Elsevier
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To evaluate the technique, efficacy, and safety of posterior iris fixation of iris-claw intraocular lens (IOLs) implantation through a scleral tunnel incision for aphakia correction. Design Noncomparative, interventional case series. Methods A secondary posterior iris fixation of the Artisan iris-claw IOL (Ophthec BV, Groningen, The Netherlands) was implanted for aphakia correction in the authors’ clinical practice. Uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), astigmatism, manifest refraction, lens position, pigment dispersion, and intraocular pressure (IOP) were evaluated in 32 consecutive eyes of 32 patients. Results BSCVA was 20/40 or better in 28 eyes (87.50%) during the mean follow-up time (nine months). Mean postoperative spherical equivalent was −0.70 diopters (D; standard deviation [SD], 0.47 D) at six months after surgery. Mean prediction error was −0.13 D (SD, 0.28 D), and mean absolute prediction error was 0.26 D (SD, 0.15 D). Preoperative mean astigmatism was −1.08 D (SD, 0.55 D; range, 0.0 to −2.0 D). At six months after surgery, mean astigmatism was −2.1 D (SD, 0.81 D; range, −0.75 to −3.75 D). There was no significant postoperative IOP increase. Lens position, evaluated by Oculus Pentacam (Pentacam 70700: Oculus, Wetzlar, Germany) and ultrasound biomicroscopy [UBM] (Ophthalmic Technologies Inc, Toronto, Ontario, Canada), was parallel to the iris plane. Conclusions Posterior iris fixation of the iris-claw IOL implantation through a scleral tunnel incision is a safe procedure and an effective option for aphakic eyes without capsule support.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9394
1879-1891
DOI:10.1016/j.ajo.2007.06.009