Intraoperative Assessment of Kidney Allograft Perfusion by Laser-Assisted Indocyanine Green Fluorescence Videography

Abstract Background Kidney allograft function crucially depends on the quality of organ perfusion. Duplex sonography, however, frequently reveals hypoperfused segments that remained undetectable to visual inspection intraoperatively. To date, no imaging system supplementing the surgeon's experi...

Full description

Saved in:
Bibliographic Details
Published inTransplantation proceedings Vol. 42; no. 5; pp. 1526 - 1530
Main Authors Hoffmann, C, Compton, F, Schäfer, J.H, Steiner, U, Fuller, T.F, Schostak, M, Zidek, W, van der Giet, M, Westhoff, T.H
Format Journal Article
LanguageEnglish
Published Amsterdam Elsevier Inc 01.06.2010
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Background Kidney allograft function crucially depends on the quality of organ perfusion. Duplex sonography, however, frequently reveals hypoperfused segments that remained undetectable to visual inspection intraoperatively. To date, no imaging system supplementing the surgeon's experience has achieved clinical acceptance. The present work examines whether laser-assisted indocyanine green (ICG) fluorescence-videography can be used as a safe and sensitive technique for the intraoperative assessment of renal allograft perfusion. Methods Intraoperative assessment of organ perfusion by laser-assisted ICG fluorescence videography (IC-VIEW) was performed in 10 consecutive de novo renal transplantations. The IC-VIEW system allows the visualization of graft perfusion by the fluorescein dye ICG that emits infrared light after exposure to laser light. Results Perfusion measurements were successful in all 10 transplant recipients. Fluorescence videography produced brilliant, sharply contrasted images of the organs, allowing the detection of even small perfusion deficits. Remarkably, this technique detected 1 large perfusion defect that had remained imperceptible to visual inspection. Repositioning of the graft led to a homogeneous overall perfusion. There were no complications with the ICG injection or the imaging device. Conclusion Laser-assisted ICG fluorescence videography is a feasible and safe technique for the intraoperative assessment of renal allograft perfusion.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0041-1345
1873-2623
DOI:10.1016/j.transproceed.2010.01.069