Influences of Sensor Placement Site and Subject Posture on Measurement of Respiratory Frequency Using Triaxial Accelerometers

Respiration frequency (RF) could be derived from the respiratory signals recorded by accelerometers which detect chest wall movements. The optimum direction of acceleration for accurate RF measurement is still uncertain. We aim to investigate the effect of measure site, posture, and direction of acc...

Full description

Saved in:
Bibliographic Details
Published inFrontiers in physiology Vol. 11; p. 823
Main Authors Hughes, Stephen, Liu, Haipeng, Zheng, Dingchang
Format Journal Article
LanguageEnglish
Published Switzerland Frontiers Media S.A 09.07.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Respiration frequency (RF) could be derived from the respiratory signals recorded by accelerometers which detect chest wall movements. The optimum direction of acceleration for accurate RF measurement is still uncertain. We aim to investigate the effect of measure site, posture, and direction of acceleration on the accuracy of accelerometer-based RF estimation. In supine and seated postures respectively, respiratory signals were measured from 34 healthy subjects in 70 s by triaxial accelerometers located at four sites on the body wall (over the clavicle, laterally on the chest wall, over the pectoral part of the anterior chest wall, on the abdomen in the midline at the umbilicus), with the reference respiratory signal simultaneously recorded by a strain gauge chest belt. RFs were extracted from the accelerometer and reference respiratory signals using wavelet transformation. To investigate the effect of measure site, posture, and direction of acceleration on the accuracy of accelerometer-based RF estimation, repeated measures multivariate analysis of variance, linear regression, Bland-Altman analysis, and Scheirer-Ray-Hare test were performed between reference and accelerometer-based RFs. There was no significant difference in accelerometer-based RF estimation between seated and supine postures, among four accelerometer sites, or between seated or supine postures ( > 0.05 for all). The error of accelerometer-based RF estimation was less than 0.03 Hz (two breaths per minute) at any site or posture, but was significantly smaller in supine posture than in seated posture ( < 0.05), with narrower limits of agreement in Bland-Altman analysis and higher accuracy in linear regression ( > 0.61 vs. < 0.51). Respiration frequency can be accurately measured from the acceleration of any direction using triaxial accelerometers placed at the clavicular, pectoral and lateral sites on the chest as well the mid abdominal site. More accurate RF estimation could be achieved in supine posture compared with seated posture.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Edited by: Massimo–Pagani, University of Milan, Italy
Reviewed by: Guanghao Sun, The University of Electro-Communications, Japan; Nizam Uddin Ahamed, University of Pittsburgh, United States
ORCID: Haipeng Liu, orcid.org/0000-0002-4212-2503
This article was submitted to Computational Physiology and Medicine, a section of the journal Frontiers in Physiology
ISSN:1664-042X
1664-042X
DOI:10.3389/fphys.2020.00823