Differential diagnosis of benign and malignant branch duct intraductal papillary mucinous neoplasm using contrast-enhanced endoscopic ultrasonography

To elucidate the role of contrast-enhanced endoscopic ultrasonography (CE-EUS) in the diagnosis of branch duct intraductal papillary mucinous neoplasm (BD-IPMN). A total of 50 patients diagnosed with BD-IPMN by computed tomography (CT) and endoscopic ultrasonography (EUS) at our institute were inclu...

Full description

Saved in:
Bibliographic Details
Published inWorld journal of gastroenterology : WJG Vol. 21; no. 20; pp. 6252 - 6260
Main Authors Harima, Hirofumi, Kaino, Seiji, Shinoda, Shuhei, Kawano, Michitaka, Suenaga, Shigeyuki, Sakaida, Isao
Format Journal Article
LanguageEnglish
Published United States Baishideng Publishing Group Inc 28.05.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To elucidate the role of contrast-enhanced endoscopic ultrasonography (CE-EUS) in the diagnosis of branch duct intraductal papillary mucinous neoplasm (BD-IPMN). A total of 50 patients diagnosed with BD-IPMN by computed tomography (CT) and endoscopic ultrasonography (EUS) at our institute were included in this study. CE-EUS was performed when mural lesions were detected by EUS. The diagnostic accuracy for identifying mural nodules (MNs) was evaluated by CT, EUS, and EUS combined with CE-EUS. In the patients who underwent resection, the accuracy of measuring MN height with each imaging modality was compared. The cut-off values to diagnose malignant BD-IPMNs based on MN height for each imaging modality were determined using receiver operating characteristic curve analysis. Fifteen patients were diagnosed with BD-IPMN with MNs and underwent resection. The remaining 35 patients were diagnosed with BD-IPMN without MNs and underwent follow-up monitoring. The pathological findings revealed 14 cases with MNs and one case without. The accuracy for diagnosing MNs was 92% using CT and 72% using EUS; the diagnostic accuracy increased to 98% when EUS and CE-EUS were combined. The accuracy for measuring MN height significantly improved when using CE-EUS compared with using CT or EUS (median measurement error value, CT: 3.3 mm vs CE-EUS: 0.6 mm, P < 0.05; EUS: 2.1 mm vs CE-EUS: 0.6 mm, P < 0.01). A cut-off value of 8.8 mm for MN height as measured by CE-EUS improved the accuracy of diagnosing malignant BD-IPMN to 93%. Using CE-EUS to measure MN height provides a highly accurate method for differentiating benign from malignant BD-IPMN.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Correspondence to: Hirofumi Harima, MD, Department of Gastroenterology and Hepatology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi 755-8505, Japan. harima@yamaguchi-u.ac.jp
Telephone: +81-836-222241 Fax: +81-836-222240
Author contributions: Harima H drafted the manuscript; Kaino S designed the study and helped draft the manuscript; Shinoda S, Kawano M and Suenaga S acquired and analyzed the data; and Sakaida I approved the final manuscript.
ISSN:1007-9327
2219-2840
DOI:10.3748/wjg.v21.i20.6252