Do Titanium Dioxide Particles Stimulate Macrophages to Release Proinflammatory Cytokines and Increase the Risk for Peri-implantitis?

Titanium dioxide (TiO2) particles detached from titanium dental implants by tribocorrosion can be phagocytosed by macrophages, releasing various proinflammatory cytokines at the implant sites that may trigger peri-implantitis. The study objective was to measure the association between peri-implantit...

Full description

Saved in:
Bibliographic Details
Published inJournal of oral and maxillofacial surgery Vol. 81; no. 3; pp. 308 - 317
Main Authors Stolzer, Carolin, Müller, Matthias, Gosau, Martin, Henningsen, Anders, Fuest, Sandra, Aavani, Farzaneh, Smeets, Ralf
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.03.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Titanium dioxide (TiO2) particles detached from titanium dental implants by tribocorrosion can be phagocytosed by macrophages, releasing various proinflammatory cytokines at the implant sites that may trigger peri-implantitis. The study objective was to measure the association between peri-implantitis and the presence of non-allergy-related proinflammatory cytokines associated with TiO2 particles. The investigators implemented a retrospective cross-sectional study and enrolled a sample of 60 subjects from a dental practice. Subjects were excluded if the plaque index was grade 3 (Silness and Löe). The predictor variable was a positive or negative TiO2 stimulation test, an in vitro macrophage proinflammatory response test. The outcome variable was peri-implantitis status defined as present or absent. Three groups were considered: control group with 20 patients without dental implants (group 1), 2 groups of patients with titanium dental implants, one without peri-implantitis (group 2), and the other with peri-implantitis (group 3) (n = 20 each). For patients with implants, depth of the gingival pockets of the implants were measured, and existing bleeding and suppuration were determined to assess peri-implantitis. Radiographs were taken if one or more factors applied to confirm the diagnosis of peri-implantitis. Further covariates were age, sex, duration of implant wear, and number of implants which were analyzed descriptively. Inferential analyses were undertaken using χ2 test, Kruskal–Wallis-, Wilcoxon-two-sample tests, and logistic regressions. The sample was composed of 35 female and 25 male patients with a mean age of 54.2 years (standard deviation = 14.76). The overall TiO2 stimulation test positivity frequency was 28.3% and were 30.0%, 5.0%, and 50.0% in the control, implants without peri-implantitis, and implants with peri-implantitis groups. No statistically significant differences could be seen in the frequencies of the TiO2 stimulation test results between control group and combined groups 2 and 3 (P-value = .84). The risk for positive TiO2 patients with a titanium implant of developing peri-implantitis was statistically significant and higher compared to negative TiO2 patients (odds ratio, 19.0 with 95% confidence interval [2.12,170.38]; P-value< .01). The data in this study showed a statistically significant relationship between a positive TiO2 stimulation test and peri-implantitis. Further studies with larger numbers of subjects are recommended to confirm this result.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0278-2391
1531-5053
1531-5053
DOI:10.1016/j.joms.2022.10.019