A rapid and highly specific immunofluorescence method to detect Escherichia coli O157:H7 in infected meat samples

Developing rapid and sensitive methods for the detection of pathogenic Escherichia coli O157:H7 remains a major challenge in food safety. The present study attempts to develop an immunofluorescence technique that uses Protein-A-coated, magnetic beads as the platform. The immunofluorescence technique...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of food microbiology Vol. 231; pp. 54 - 62
Main Authors Balakrishnan, Baskar, Barizuddin, Syed, Wuliji, Tumen, El-Dweik, Majed
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 16.08.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Developing rapid and sensitive methods for the detection of pathogenic Escherichia coli O157:H7 remains a major challenge in food safety. The present study attempts to develop an immunofluorescence technique that uses Protein-A-coated, magnetic beads as the platform. The immunofluorescence technique described here is a direct detection method in which E. coli O157:H7 cells are labeled with tetramethylrhodamine (TRITC) fluorescent dye. TRITC-labeled bacteria are captured by the desired antibody (Ab), which is immobilized on the Protein-A magnetic beads. Fluorescence of the captured cells is recorded in a fluorescence spectrophotometer, where the fluorescence values are shown to be directly proportional to the number of bacteria captured on the immunobead. The formation of an immunocomplex is evidenced by the fluorescence of the beads under microscopy. The Ab immobilization procedure is also evidenced by microscopy using fluorescein isothiocyanate (FITC)-labeled Ab. The total experimental time, including preparation of the sample, is just 1h. The minimum bacterial concentration detected by this method is 1.2±0.06×103CFUml−1. The high specificity of this method was proved by using the specific monoclonal Ab (MAb) in the test. The proposed protocol was successfully validated with E. coli O157:H7-infected meat samples. This approach also opens the door for the detection of other bacterial pathogens using Protein-A magnetic beads as a detection platform. •A magnetic beads-based immunofluorescence method was developed to detect E. coli O157:H7 in meat.•This direct detection method targets TRITC-labeled whole cell antigen.•Rapid detection takes just 1h, using fluorescence microscopy and spectrofluorometry.•High specificity is achieved by using Protein-A and a specific mouse monoclonal antibody.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0168-1605
1879-3460
DOI:10.1016/j.ijfoodmicro.2016.05.017