Pulmonary function tests do not predict mortality in patients undergoing continuous-flow left ventricular assist device implantation

Abstract Objectives To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. Methods A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of thoracic and cardiovascular surgery Vol. 154; no. 6; pp. 1959 - 1970.e1
Main Authors Bedzra, Edo K.S., MD, MBA, Dardas, Todd F., MD, MS, Cheng, Richard K., MD, MS, Pal, Jay D., MD, PhD, Mahr, Claudius, DO, Smith, Jason W., MD, Shively, Kent, BS, Masri, S. Carolina, MD, Levy, Wayne C., MD, Mokadam, Nahush A., MD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.12.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Objectives To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. Methods A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. Results There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P  = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis ( P  = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. Conclusions Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0022-5223
1097-685X
DOI:10.1016/j.jtcvs.2017.02.069