Model-based iterative reconstruction: effect on patient radiation dose and image quality in pediatric body CT

To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection...

Full description

Saved in:
Bibliographic Details
Published inRadiology Vol. 270; no. 2; pp. 526 - 534
Main Authors Smith, Ethan A, Dillman, Jonathan R, Goodsitt, Mitchell M, Christodoulou, Emmanuel G, Keshavarzi, Nahid, Strouse, Peter J
Format Journal Article
LanguageEnglish
Published United States Radiological Society of North America 01.02.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection. Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified. Images were reconstructed with two algorithms: MBIR and 100% ASIR. All subjects had undergone standard-dose CT within the prior year, and the images were reconstructed with 30% ASIR. Reduced- and standard-dose images were evaluated objectively and subjectively. Reduced-dose images were evaluated for lesion detectability. Spatial resolution was assessed in a phantom. Radiation dose was estimated by using volumetric CT dose index (CTDI(vol)) and calculated size-specific dose estimates (SSDE). A combination of descriptive statistics, analysis of variance, and t tests was used for statistical analysis. In the 25 patients who underwent the reduced-dose protocol, mean decrease in CTDI(vol) was 46% (range, 19%-65%) and mean decrease in SSDE was 44% (range, 19%-64%). Reduced-dose MBIR images had less noise (P > .004). Spatial resolution was superior for reduced-dose MBIR images. Reduced-dose MBIR images were equivalent to standard-dose images for lungs and soft tissues (P > .05) but were inferior for bones (P = .004). Reduced-dose 100% ASIR images were inferior for soft tissues (P < .002), lungs (P < .001), and bones (P < .001). By using the same reduced-dose acquisition, lesion detectability was better (38% [32 of 84 rated lesions]) or the same (62% [52 of 84 rated lesions]) with MBIR as compared with 100% ASIR. CT performed with a reduced-dose protocol and MBIR is feasible in the pediatric population, and it maintains diagnostic quality.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Author contributions: Guarantors of integrity of entire study, E.A.S., J.R.D., E.G.C.; study concepts/study design or data acquisition or data analysis/interpretation, all authors; manuscript drafting or manuscript revision for important intellectual content, all authors; approval of final version of submitted manuscript, all authors; literature research, E.A.S., J.R.D., M.M.G.; clinical studies, E.A.S., J.R.D.; experimental studies, M.M.G., E.G.C.; statistical analysis, M.M.G., N.K.; and manuscript editing, E.A.S., J.R.D., M.M.G., E.G.C., N.K.
ISSN:0033-8419
1527-1315
DOI:10.1148/radiol.13130362